PC/PCL Series Low-expansion Foam Generator
video
PC/PCL Series Low-expansion Foam Generator

PC/PCL Series Low-expansion Foam Generator

The PC/PCL series low-expansion foam generator is the core foaming component of low-expansion foam fire suppression systems, available in two categories: vertical (PCL series) and horizontal (PC series). Its main body is integrally cast from QT450-10 ductile iron, with a heavy anti-corrosion finish of "epoxy zinc-rich primer + polyurethane topcoat". Compatible with a working pressure range of 0.3-0.6MPa, it converts foam mixture into low-expansion foam with an expansion ratio ≥5, specifically designed to extinguish fires involving flammable liquids (e.g., crude oil, gasoline, diesel). It is suitable for scenarios such as petroleum tank farms, chemical production workshops, and large-scale flammable liquid storage facilities.

Description

Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of pc/pcl series low-expansion foam generator in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.

 

Products Description

 

product-800-800
 
 

PC/PCL series low-expansion foam generator

The PC/PCL series low-expansion foam generator is the core foaming component of low-expansion foam fire suppression systems, available in two categories: vertical (PCL series) and horizontal (PC series). Its main body is integrally cast from QT450-10 ductile iron, with a heavy anti-corrosion finish of "epoxy zinc-rich primer + polyurethane topcoat". Compatible with a working pressure range of 0.3-0.6MPa, it converts foam mixture into low-expansion foam with an expansion ratio ≥5, specifically designed to extinguish fires involving flammable liquids (e.g., crude oil, gasoline, diesel). It is suitable for scenarios such as petroleum tank farms, chemical production workshops, and large-scale flammable liquid storage facilities.

 

Applications & Working Principle

Model Structure Type Rated Mixture Flow Rate (L/s) Working Pressure Range (MPa) Flow Series (K) Water Inlet Flange Spec Water Outlet Flange Spec Height of Outlet Flange Center (mm) Foam Expansion Ratio
PCL4 Vertical 4 0.3-0.6 107 DN50 (1.6MPa) DN65 (0.6MPa) 320 ≥5
PCL8 Vertical 8 0.3-0.6 215 DN65 (1.6MPa) DN80 (0.6MPa) 350 ≥5
PCL16 Vertical 16 0.3-0.6 429 DN100 (1.6MPa) DN125 (0.6MPa) 395 ≥5
PCL24 Vertical 24 0.3-0.6 644 DN125 (1.6MPa) DN150 (0.6MPa) 420 ≥5
PC4 Horizontal 4 0.3-0.6 107 R2 DN65 220 ≥5
PC8 Horizontal 8 0.3-0.6 215 R2 1/2 DN80 225 ≥5
PC16 Horizontal 16 0.3-0.6 429 R3 DN125 230 ≥5
PC24 Horizontal 24 0.3-0.6 644 R4 DN150 240 ≥5
 
product-800-800

product-800-800

Structural & Material Advantages

 

product-800-800

 

 

Ductile Iron Main Body Performance

Made of QT450-10 ductile iron, it has a tensile strength ≥450MPa and elongation after fracture ≥10% - its impact resistance is 40% higher than traditional gray cast iron. The heavy anti-corrosion coating has a salt spray resistance of ≥800 hours, enabling long-term use in corrosive environments such as outdoor tank farms and coastal chemical zones.

Differentiated Structural Design

Vertical PCL series: Adopts a vertical layout, occupying minimal horizontal space, suitable for fixed installation on the top of petroleum storage tanks;

Horizontal PC series: Uses a horizontal pipeline layout, which can be directly connected in series with fire pipeline branches, ideal for foam sprinkler systems in workshops and warehouses;

Built-in stainless steel filter: Effectively intercepts impurities in the mixture, preventing blockage of foaming components and ensuring uniform foam generation.

 

 

FAQ

Q: What is the detection distance?A: The maximum monitoring radius is 70m (different models are 40m, 65m, and 70m respectively), which can cover long-distance fire detection in large spaces.

Q: What are the requirements for installation height?A: Different models have different requirements, ranging from 6 to 35m (for example, ZDMS0.6/5S is 6~20m, and ZDMS0.8/50S is 8~35m). The selection should be based on the model and the height of the venue.

Q: Can it work during a power outage?A: The equipment relies on external power supply. It is recommended to be equipped with an emergency fire power supply to ensure short-term operation in case of a power failure.

Q: How to confirm that the equipment is working normally?A: Regularly test the detection and water spraying functions with a flame simulator, and check the device status indicators/control system feedback to ensure there are no fault alarms.

Q: What types of fires can it extinguish?A: It is suitable for Class A solid fires (such as fires involving wood, paper, and cloth). Specific applications should be confirmed in accordance with fire protection design specifications.

How To Cooperate With Us?
 

Our address

NO.8, YUANFENG ROAD, MEIYUAN VILLAGE, KANGMEI TOWN, NANAN CITY, QUANZHOU CITY, FUJIAN CHINA

 
WhatsApp

+86 15880910562

 

E-mail

sales7@ca-fire.com

product-943-596

Get a Quote

 

 

 

Hot Tags: pc/pcl series low-expansion foam generator, China pc/pcl series low-expansion foam generator manufacturers, suppliers, factory, Low Expansion Foam Chamber, Air Foam Chamber, Foam System Firefighting Foam Chamber, Foam Chamber

You Might Also Like

Shopping Bags