CA-FIRE provides a comprehensive range of fire sprinkler heads designed to meet diverse fire protection requirements across residential, commercial, and industrial applications. With 30+ models available, our portfolio covers all standard installation types, from light hazard environments to large-scale warehouse systems.
All sprinkler heads are manufactured in-house at our Fujian facility, ensuring stable quality control and reliable performance. Our products comply with GB 5135 standards, and selected export models are supported with English technical documentation aligned with National Fire Protection Association project requirements.
This page serves as a complete overview of our sprinkler product range. You can browse by installation type, response rating, or application scenario, and quickly navigate to the most suitable product for your project.
All products listed on this page are standard (non-FM/UL) glass bulb and fusible link sprinklers. For FM Approved sprinkler heads, see our FM certified fire sprinkler range
We offer logo printing and custom packaging with low MOQ and samples available.
We have a professional QC team to control quality.
Shipped within 10~40 days after payment, depending on product and quantity.
We ship via major couriers and air/sea freight.
24/7 customer service with friendly staff and trained sales team.
FM Approved Fire Sprinkler Heads
NF3151 Upright Fire Sprinkler Head
Installed upright on the branch pipe with the deflector facing upward to produce a dome-shaped water distribution pattern. This FM approved sprinkler is suitable for industrial environments with exposed piping, providing reliable performance in areas where structural conditions require upright installation. Each sprinkler can cover up to 20 m². Available in K5.6 (K80).
NF3251 Pendent Fire Sprinkler Head
Hangs below the branch pipe with the deflector oriented downward to deliver a uniform spray pattern. This FM approved standard response sprinkler is widely used in commercial and industrial ceiling installations, offering stable and dependable fire protection performance for general applications. Each sprinkler can cover up to 20 m². Available in K5.6 (K80).
NF3351 Sidewall Fire Sprinkler Head
Installed along the sidewall with the deflector designed to discharge water outward in a half-parabolic spray pattern. This FM approved sprinkler is ideal for spaces where ceiling installation is not feasible, such as corridors, offices, and small rooms, ensuring effective lateral coverage. Each sprinkler can cover up to 20 m². Available in K5.6 (K80).
NF3131 Upright Fire Sprinkler Head
Installed upright with the deflector facing upward, this fast-response FM sprinkler combines upright installation flexibility with rapid activation. It is particularly suitable for industrial facilities where both quick response and exposed piping conditions are required. Each sprinkler provides coverage up to 20 m². Available in K5.6 (K80).
NF3231 Pendent Fire Sprinkler Head
Hangs below the branch pipe with the deflector oriented downward, featuring a fast-response 3mm glass bulb for quicker activation. This model is ideal for environments where early fire suppression is critical, helping to reduce heat release and limit fire spread at an early stage. Each sprinkler can cover up to 20 m². Available in K5.6 (K80).
NF3331 Sidewall Fire Sprinkler Head
Installed on the sidewall with a fast-response 3mm glass bulb, this sprinkler provides rapid activation combined with horizontal water distribution. It is well suited for confined or compartmentalized spaces where quick fire control is essential. Each sprinkler provides coverage up to 20 m². Available in K5.6 (K80).
Standard Response Fire Sprinkler Heads
Pendent Fire Sprinkler Head
T-ZSTX 115-68°C Q5 J
Hangs below the branch pipe with the deflector oriented downward to deliver a uniform spray pattern. This is the most commonly specified sprinkler type for commercial and industrial ceiling installations. Each sprinkler can cover up to 20 m². Available in K5.6 (K80), K8.0 (K115), and K11.2 (K161) options.
Upright Fire Sprinkler Head
T-ZSTZ115-68°C Q5 J
Installed upright on the branch pipe with the deflector facing upward to distribute water in a dome-shaped spray pattern. This type is commonly used in industrial applications where piping is exposed or subject to freezing conditions. Each sprinkler can cover up to 20 m². Available in K5.6 (K80), K8.0 (K115), and K11.2 (K161) options.
Sidewall Fire Sprinkler Head
T-ZSTBS 115-68°C Q5J
Installed along the sidewall with the deflector positioned to discharge water outward in a half-parabolic spray pattern. Designed for areas where ceiling installation is not practical, such as corridors, small rooms, and offices. Each sprinkler can cover up to 20 m². Available in K5.6 (K80), K8.0 (K115), and K11.2 (K161) options.
Pendent Fire Sprinkler Head
ZSTX 115-121°C Q5
Designed for high-temperature environments, this sprinkler features a 121°C (250°F) thermal rating to prevent false activation under elevated ambient conditions. It is ideal for applications such as boiler rooms, mechanical spaces, commercial kitchens, and industrial facilities where heat buildup is common. The higher activation temperature ensures reliable performance while still providing effective fire suppression when needed. Available in K5.6 (K80), K8.0 (K115), and K11.2 (K161) options.
Pendent Fire Sprinkler Head
ZSTX 115-182°C Q5
Engineered for extreme high-temperature environments, this sprinkler features a 182°C (360°F) thermal rating to withstand intense ambient heat without premature activation. It is ideal for applications such as furnace areas, industrial drying equipment, high-temperature manufacturing zones, and attic spaces exposed to significant heat accumulation. The elevated activation threshold ensures dependable operation only under true fire conditions while maintaining effective fire suppression performance. Available in K5.6 (K80), K8.0 (K115), and K11.2 (K161) options.
Pendent Fire Sprinkler Head
ZSTX 115-260°C Q5
Designed for ultra high-temperature environments, this sprinkler features a 260°C (500°F) thermal rating, making it suitable for extreme-heat applications such as foundries, steel mills, oven areas, and industrial furnaces. Its high activation temperature prevents accidental discharge in areas with intense ambient heat, ensuring reliable operation only during actual fire events. Available in K5.6 (K80), K8.0 (K115), and K11.2 (K161) options.
Quick Response Fire Sprinkler Heads
Pendent Fire Sprinkler Head
K-ZSTX 80-68°C Q3 J
Hangs below the branch pipe with the deflector facing downward, featuring a fast-response design for quicker activation in the early stages of a fire. Ideal for commercial and industrial ceilings where rapid detection and suppression are critical to minimize fire damage. Each sprinkler covers up to 20 m². Available in K5.6 (K80), K8.0 (K115), and K11.2 (K161) options.
Upright Fire Sprinkler Head
K-ZSTZ 80-68°C Q3 J
Installed upright on the branch pipe with the deflector facing upward, this fast-response sprinkler activates quickly to suppress fires in the early stages, making it ideal for commercial and industrial areas where rapid fire control is critical. Each sprinkler provides coverage up to 20 m². Available in K5.6 (K80), K8.0 (K115), and K11.2 (K161) options.
Sidewall Fire Sprinkler Head
K-ZSTBS 80-68°C Q3 J
Installed on the sidewall with the deflector directing water outward in a half-parabolic spray pattern, this fast-response sidewall sprinkler activates quickly to control fires at an early stage. It is ideal for corridors, small rooms, offices, and other areas where ceiling installation is not practical. Each sprinkler provides coverage up to 20 m². Available in K5.6 (K80), K8.0 (K115), and K11.2 (K161) options.
Special Application Fire Sprinklers
Industrial Fire Sprinkler
CHSAK-X 161-68℃ Q3
The CHSAK-X 161-68°C Q3 is a fast-response industrial fire sprinkler designed for large commercial and industrial spaces. Featuring a K-factor of K11.2 (K161), it delivers high water flow for effective early fire suppression.
Equipped with a 3mm glass bulb (Q3), it ensures rapid activation at 68°C, helping to control fire growth quickly. Suitable for factories, warehouses, shopping malls, and other open areas.
Fusible Link Sprinkler Head
CHSAZ 242-74℃ Y
The CHSAZ 242-74°C Y is a fusible link sprinkler designed for industrial and commercial fire protection. With a K-factor of K16.8 (K242), it provides high water discharge for effective fire control in large open areas.
Activated by a fusible link at 74°C, it ensures reliable performance in environments where durability and stable operation are required. Suitable for warehouses, factories, and other high-risk areas.
Dry Sprinkler Head
T-ZSTGX 115-68°C Q5
The T-ZSTGX 115-68°C Q5 is a dry sprinkler designed for areas exposed to freezing conditions. With a K-factor of K8.0 (K115), it provides reliable water discharge for effective fire protection.
Equipped with a 5mm glass bulb (Q5), it activates at 68°C and prevents water from entering the pipe until operation, reducing the risk of freezing. Ideal for cold storage facilities, unheated warehouses, and outdoor installations.
Centrifugal Water Spray Nozzle ZSTMA-T10 T21.5
The ZSTMA-T10 / T21.5 centrifugal water spray nozzle is designed for fire protection and cooling applications. It produces a uniform fine water spray through centrifugal force, ensuring effective coverage and heat absorption.
Suitable for use in water spray systems for transformers, petrochemical facilities, and industrial equipment protection. Its reliable performance makes it ideal for both fire suppression and cooling purposes.
Impact Water Spray Nozzle
ZSTW C16/90
The ZSTW C16/90 impact water spray nozzle is designed for fire protection and cooling in industrial applications. It produces a medium-velocity water spray through an impact deflector, ensuring effective coverage and heat absorption.
Widely used in water spray systems for transformers, petrochemical plants, and hazardous equipment protection. Its durable design provides stable and reliable performance in demanding environments.
Foam Sprinkler Head
PT0.9
The PT0.9 foam sprinkler head is designed for foam fire suppression systems, providing effective protection for flammable liquid hazards. It discharges a uniform foam solution to rapidly cover the fire surface and suppress vapors.
Widely used in applications such as fuel storage areas, petrochemical facilities, and industrial plants. Its stable performance ensures reliable fire control in high-risk environments.
Early Suppression Fast Response ESFR-242 74°C P
The ESFR-242 74°C P is an early suppression fast response sprinkler designed for high-piled storage and warehouse applications. With a K-factor of K16.8 (K242), it delivers high water discharge to suppress fires at an early stage.
Activated at 74°C, it provides rapid response and strong penetration, reducing the need for in-rack sprinklers. Ideal for logistics centers, distribution warehouses, and storage facilities with high fire loads.
Fusible Link Sprinkler Head
ZSTZ 80-72°C Y
The ZSTZ 80-72°C Y is a fusible link sprinkler designed for reliable fire protection in commercial and industrial applications. With a K-factor of K5.6 (K80), it provides stable and efficient water discharge.
Activated by a fusible link at 72°C, it ensures dependable operation in environments requiring robust and durable performance. Suitable for warehouses, factories, and general indoor fire protection systems.
Deluge Sprinkler (Open Nozzle)
B-DSXC-281
The B-DSXC-281 deluge sprinkler is an open-type nozzle designed for deluge fire protection systems. Without a thermal element, it allows immediate water discharge when the system is activated, ensuring rapid response to fire emergencies.
It provides wide-area coverage and is ideal for high-hazard environments such as petrochemical plants, power stations, and industrial facilities where fast fire control is critical.