CMSA Series Warehouse Special Application Sprinklers
CMSA series is a control-mode special application fire sprinkler for high-bay warehouses and large spaces. Featuring multiple K-factors, low-pressure operation and 68°C/74°C temperature grades, it reliably controls fire spread, suits 12m high ceilings, and is fully UL/FM certified for industrial storage fire protection.
Description
Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of cmsa series warehouse special application sprinklers in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.
Products Description

CMSA Series Warehouse Special Application Sprinklers
The CMSA Series is a range of special application sprinklers designed for high-challenge warehouse environments. Available in pendant (X) and upright (Z) configurations, the series covers K-factors from K161 to K363 for installation heights up to 12.0 meters. Dual temperature ratings of 68°C and 74°C accommodate varied ambient conditions, while Q5 quick response options deliver rapid fire control where needed. Fully certified to GB 5135.9-2018 standards, CMSA sprinklers provide reliable protection for distribution centers, cold storage, pharmaceutical warehouses, and high-bay storage facilities.
What is CMSA Technology?
CMSA sprinklers operate on the control mode principle: rather than attempting immediate fire suppression, they are engineered to control fire growth by cooling surrounding areas and pre-wetting adjacent combustibles. This approach limits fire spread to a manageable size until firefighting personnel arrive.
Unlike ESFR sprinklers that require high pressure for rapid suppression, CMSA sprinklers deliver superior water discharge at lower operating pressures through large K-factors, making them ideal for protecting high-piled storage up to 12 meters in height.
Technical Specifications
|
Parameter |
CMSAX/CMSAZ 161 |
CMSAX/CMSAZ 242 |
CMSAX/CMSAZ 363 |
|---|---|---|---|
| K-Factor (Metric) | K161 L/min·MPa⁻½ | K242 L/min·MPa⁻½ | K363 L/min·MPa⁻½ |
| K-Factor (Imperial) | K11.2 gpm·psi⁻½ | K16.8 gpm·psi⁻½ | K25.2 gpm·psi⁻½ |
| Nominal Diameter | DN20 (3/4") | DN20 (3/4") | DN25 (1") |
| Thread Connection | R3/4" / NPT 3/4" | R3/4" / NPT 3/4" | R1" / NPT 1" |
| Temperature Ratings | 68°C, 74°C | 68°C, 74°C | 68°C, 74°C |
| Response Type | Standard Response | Standard Response | Standard Response |
| RTI Index | 80 < RTI ≤ 150 (m·s)⁰·⁵ | 80 < RTI ≤ 150 (m·s)⁰·⁵ | 80 < RTI ≤ 150 (m·s)⁰·⁵ |
| Max Working Pressure | 1.2 MPa (174 psi) | 1.2 MPa (174 psi) | 1.2 MPa (174 psi) |
| Factory Test Pressure | 3.0 MPa hydrostatic (100% tested) | 3.0 MPa hydrostatic (100% tested) | 3.0 MPa hydrostatic (100% tested) |
| Body Material | Lead-free Forged Brass, Nickel Plated Optional | Lead-free Forged Brass, Nickel Plated Optional | Lead-free Forged Brass, Nickel Plated Optional |
| Deflector Material | Stainless Steel | Stainless Steel | Stainless Steel |
| Frame Finish | Natural Brass / White / Chrome Plated | Natural Brass / White / Chrome Plated | Natural Brass / White / Chrome Plated |
| Installation Types | Pendent (X), Upright (Z) | Pendent (X), Upright (Z) | Pendent (X), Upright (Z) |
Installation Guidelines


Proper installation procedures per NFPA 13 and manufacturer specifications General Installation Requirements
1 System Compatibility
CMSA sprinklers are approved for use in wet pipe, dry pipe, and preaction sprinkler systems. All installations must comply with NFPA 13 Chapter 13 requirements and the specific sprinkler listing criteria.
2 Deflector Positioning
Unobstructed construction: Deflectors must be positioned 150-200mm (6-8 inches) below ceiling. Obstructed construction: Deflectors must be 150-300mm (6-12 inches) below ceiling with maximum 550mm (22 inches) from structural members.
3 Spacing Requirements
Maximum spacing between sprinklers: 3.0m x 3.0m (10ft x 10ft) for standard coverage. Minimum spacing: 2.4m (8ft) between sprinklers. Always refer to manufacturer's listing for specific spacing criteria.
4 Temperature Selection
Select temperature rating at least 30°C (54°F) above maximum expected ambient temperature. 68°C rating for ambient ≤ 38°C; 74°C rating for ambient ≤ 44°C.
Important Notes & Warnings
Critical Installation Warnings
- Never paint sprinklers - paint can prevent proper operation
- Do not install damaged or dropped sprinklers - replace immediately
- Never bend frame arms or deflectors - this affects spray pattern
- Glass bulbs are pressure-sensitive - handle with extreme care
- Do not mix sprinkler types within the same design area
Torque Specifications
Reference Standards
- • NFPA 13 - Standard for Installation of Sprinkler Systems
- • UL 199 - Standard for Automatic Sprinklers for Fire Protection
- • FM Approval Standard for Sprinklers
- • GB 5135 - Automatic Fire Sprinkler System (China)
FAQ