High-Quality Concealed Fire Sprinkler With Imported Glass Bulb For Aesthetic Ceiling Applications
video
High-Quality Concealed Fire Sprinkler With Imported Glass Bulb For Aesthetic Ceiling Applications

High-Quality Concealed Fire Sprinkler With Imported Glass Bulb For Aesthetic Ceiling Applications

The concealed fire sprinkler features a high-quality glass bulb for accurate temperature response and reliable activation. Designed for aesthetic ceiling installations, it is ideal for hotels, offices, and commercial spaces. Multiple K-factors and temperature ratings ensure flexible system design and effective fire protection.

Description

Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of high-quality concealed fire sprinkler with imported glass bulb for aesthetic ceiling applications in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.

 

Products Description

 

product-800-800
 
 

CA-FIRE Concealed Fire Sprinkler

The concealed fire sprinkler is designed to combine reliable fire protection with superior architectural aesthetics. It is equipped with a high-quality imported glass bulb, ensuring precise temperature response and stable activation performance under fire conditions.

This concealed sprinkler is ideal for installations where appearance is a key concern. When installed, the sprinkler is hidden above the ceiling and covered by a decorative cover plate, maintaining a clean and elegant interior design. It is widely used in hotels, office buildings, clubs, entertainment centers, and other high-end commercial spaces.

In addition, the concealed design makes it especially suitable for areas with limited ceiling clearance caused by structural or HVAC constraints. It also reduces the risk of accidental impact or damage in crowded environments or locations with frequent goods handling.

With high manufacturing standards and reliable performance, this concealed sprinkler provides an effective fire suppression solution without compromising interior aesthetics.

 
Item Specification
Flow Coefficient (K-Factor) K = 80 / K = 115
Nominal Operating Temperature 57°C / 68°C / 79°C / 93°C / 141°C
Maximum Ambient Temperature 27°C / 38°C / 49°C / 63°C / 111°C
Glass Bulb Color Orange / Red / Yellow / Green / Blue
Connection Thread Rp 1/2 (K=80) ; Rp 3/4 (K=115)
Sensing Element Glass Bulb (5mm / 3mm)
Minimum Ambient Temperature 4°C
Response Time Index (RTI) 5mm Bulb: 50–80 (m·s)0.53mm Bulb: ≤ 50 (m·s)0.5
Installation Type Pendent (Concealed Type)

Application & Advantages

The concealed fire sprinkler is engineered to blend high-performance fire suppression with premium architectural aesthetics.

Key Advantages

Seamless Integration: The sprinkler is installed above the ceiling and finished with a decorative cover plate, maintaining a clean, elegant, and unobstructed interior design.

High-Quality Components: Equipped with a premium imported glass bulb to ensure precise thermal sensitivity and stable, reliable activation during a fire.

Space-Efficient Design: The low-profile concealed structure is ideal for installations with limited ceiling clearance due to structural beams or HVAC ducting.

Enhanced Protection: The recessed design and cover plate significantly reduce the risk of accidental mechanical impact or tampering in high-traffic areas.

Ideal Applications

High-End Commercial Spaces: Perfect for luxury hotels, Grade-A office buildings, private clubs, and high-end retail.

Public Venues: Suitable for entertainment centers, theaters, and galleries where aesthetics are a priority.

High-Traffic Areas: Recommended for environments with frequent goods handling or crowded corridors where traditional sprinklers might be prone to damage.

 

product-800-800

product-800-800

 

 

Installation Requirements

1. Pre-Installation Inspection

Check for Damage: Ensure the glass bulb is intact and the sprinkler frame is not bent or distorted. Never install a sprinkler that has been dropped or shows signs of leakage.

Match Specifications: Verify that the temperature rating and K-factor match the design requirements of the specific zone.

2. Proper Tooling

Specialized Wrench: Use only the manufacturer-specified sprinkler wrench to tighten the unit into the fitting. Using standard pliers or pipe wrenches can damage the frame and cause premature activation or leaks.

Torque Control: Do not over-tighten. Excessive torque can cause the threaded connection to crack or the sprinkler seal to fail.

3. Positioning and Clearance

Ceiling Alignment: The sprinkler must be installed at the correct depth relative to the ceiling. The distance between the sprinkler and the decorative cover plate must be strictly maintained according to the technical drawings to ensure the cover plate drops away correctly during a fire.

Avoid Obstructions: Ensure there are no HVAC vents, light fixtures, or structural beams blocking the spray pattern of the sprinkler.

4. Cover Plate Installation

Strictly Prohibited: Never paint, plate, or coat the decorative cover plate. Any modification will change the melting point of the solder, preventing the cover from releasing and potentially causing the system to fail.

Snug Fit: Ensure the cover plate is securely attached to the mounting ring/cup, sitting flush against the ceiling for a clean finish.

5. Environmental Constraints

Temperature Limits: Do not install sprinklers in areas where the ambient temperature exceeds the "Max. Ambient Temperature" listed in the technical table (e.g., do not use a 68°C bulb in a room that stays at 50°C).

Anti-Freeze: The system must be maintained at a minimum temperature of 4°C to prevent water in the pipes from freezing and damaging the glass bulb.

6. Hydrostatic Testing

The piping system should be pressure-tested before the decorative cover plates are installed to check for leaks at the threaded connections.

  OUR CERTIFICATE:

product-570-806
product-570-806
product-570-806
 
 
How To Cooperate With Us?
 

Our address

NO.8, YUANFENG ROAD, MEIYUAN VILLAGE, KANGMEI TOWN, NANAN CITY, QUANZHOU CITY, FUJIAN CHINA

 

Phone Number

+86 15960762930

 

E-mail

alison@ca-fire.com

product-943-596

 

Learn More

 

 

 

 

 

Hot Tags: high-quality concealed fire sprinkler with imported glass bulb for aesthetic ceiling applications, China high-quality concealed fire sprinkler with imported glass bulb for aesthetic ceiling applications manufacturers, suppliers, factory, Concealed Sprinkler, Fire Sprinklers, Concealed Fire Sprinkler

You Might Also Like

Shopping Bags