CA-FIRE PSKD-CA/BU Series Electrically Controlled Fixed Fire Monitor Product Introduction For PSKD-CA/BU Series Electrically Controlled Fixed Fire Monitor (Models: PSKD8/30W-CA/BU, PSKD8/40W-CA/BU, PSKD8/50W-CA/BU, PSKD10/60W-CA/BU) 0. Company Introduction CA-FIRE Fire Protection Co., LTD,...

Description

Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of ca-fire pskd-ca/bu series electrically controlled fixed fire monitor product in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.

 

CA-FIRE PSKD-CA/BU Series Electrically Controlled Fixed Fire Monitor Product Introduction

For PSKD-CA/BU Series Electrically Controlled Fixed Fire Monitor (Models: PSKD8/30W-CA/BU, PSKD8/40W-CA/BU, PSKD8/50W-CA/BU, PSKD10/60W-CA/BU)

0. Company Introduction

CA-FIRE Fire Protection Co., LTD, founded in 2012 and located in Quanzhou, China, specializes in the research, development, and manufacturing of high-quality firefighting equipment. Our product portfolio covers FM-certified fire sprinklers, hydrants, alarm valves, foam systems, and CCC/CE-certified nozzles. We are committed to delivering dependable, long-lasting, and compliant fire safety solutions for residential, commercial, and industrial properties across the globe.CA-FIRE's product range caters to diverse fire protection demands, including Fire Sprinklers; Indoor & Outdoor Fire Hydrants; Alarm Valves (Wet/Deluge/Explosion-Proof Types); Foam Systems (Bladder Tanks, Generators); Fire Nozzles, Water Monitors & Hoses; Hose Reels, Couplings & Accessories; and Intelligent Electrically Controlled Fire Monitors (Fixed Type). Every product undergoes rigorous quality control and adheres to GB19156-2019 and GB19157-2003 national standards, with customizable sizes and solutions available to fit specific project needs.

1. Product Overview & Core Advantages

1.1 Product Overview

The PSKD-CA/BU Series Electrically Controlled Fixed Fire Monitor is an intelligent fire suppression device integrating multi-mode control, video monitoring, and dual spray functions. It consists of a control system, electrically controlled monitor main body, power supply system, and optional camera-supporting three control modes: on-site manual control, remote wired control (CAN bus), and wireless remote control. Designed to protect firefighters by enabling safe-distance operation, it features worm and worm gear transmission for stable, low-noise rotation with self-locking capability. The monitor head supports switching between DC columnar (long-distance) and foggy (wide-coverage) spray modes, with 0~360° horizontal rotation and -85°~+85° vertical rotation for full-range coverage. Optional video function allows remote image capture and storage via the centralized control host. Available in seated and hanging installation (hanging requires advance communication), it is widely used in industrial and mining enterprises, petrochemical facilities, ports, oil storage areas, coal yards, and large warehouses.

1.2 Core Advantages

Triple Control Modes: On-site manual, remote wired (CAN bus, ≥200m), and wireless remote control (150m) for flexible operation in diverse scenarios-ensuring safe, efficient fire suppression from a distance.

Intelligent Functions: Optional video monitoring for remote scene observation; A/B point self-swing function (sets swing range between two points) for automatic coverage of large areas.

Superior Transmission & Rotation: Worm and worm gear transmission offers high efficiency, stable operation, low noise, and self-locking-preventing misrotation from recoil.

Full-Range Coverage: 0~360° horizontal rotation and -85°~+85° vertical rotation (wider than standard models) plus ≥90° maximum spray angle-eliminating coverage blind spots.

Dual Spray Modes: Electrically switch between DC columnar (targeted long-distance suppression) and foggy (short-range wide coverage) modes to adapt to different fire sizes.

Compliant & Reliable: Meets GB19156-2019 and GB19157-2003 national standards; IP-compatible design with stable performance in 4℃~55℃ working temperature.

2. Technical Specifications

Specification Category Details
Model Series PSKD8/30W-CA/BU, PSKD8/40W-CA/BU, PSKD8/50W-CA/BU, PSKD10/60W-CA/BU
Rated Flow PSKD8/30W:30L/s; PSKD8/40W:40L/s; PSKD8/50W:50L/s; PSKD10/60W:60L/s
Spray Range PSKD8/30W:60m; PSKD8/40W:65m; PSKD8/50W:70m; PSKD10/60W:75m
Rated Working Pressure 0.8MPa, 1.0MPa
Maximum Allowable Working Pressure 1.6MPa
Maximum Spray Angle ≥90°
Horizontal Rotation Angle 0~360° (adjustable)
Vertical Rotation Angle -85°~+85°
Power Supply Input: AC220V; Working Voltage: DC24V
Control Distance Wired: ≥200m (CAN bus); Wireless: 150m
Video Function Optional (supports on-site image capture/storage)
Inlet Size DN80
Working Temperature 4℃~55℃
Overall Dimension 600×700×900mm
Weight PSKD8/30W:23kg; PSKD10/60W:25kg
Installation Modes Seated installation (standard); Hanging installation (optional, advance communication required)
Executive Standards GB19156-2019, GB19157-2003
Certifications CCC, CE

3. Installation, Operation & Maintenance Guidelines

3.1 Installation Requirements

Pre-Installation Preparation: Install only after pipeline pressure testing and flushing are qualified; each monitor must be equipped with a manual valve and an electric valve.

Installation Space: For seated installation, the distance from the monitor's rotation axis to the wall ≥700mm; the distance from the anti-sway bracket's fixed point to the flange is 100mm~300mm.

Flange Alignment: Adjust the butt flange end face to horizontal with a level during installation to ensure stable rotation.

Wiring Notes: Video cables use CAT5 network cables (same as security systems); for distances exceeding 100m, use switches or fiber optic transmission.

Hanging Installation: If choosing hanging installation, confirm technical details with the manufacturer in advance to ensure structural compatibility.

3.2 Operation Instructions

3.2.1 Control Components & Functions

On-Site Control Box (CA-PSKD/SKX/BS): One-to-one management with basic operations (up/down/left/right, fog/column mode, pump/valve start/stop, reset) and A/B point self-swing programming. Set addresses via internal dip switches (binary).

Wireless Remote Controller (YKFS/B2.4G-CA150): Manages multiple monitors by selecting addresses (001~XXX); functions identical to the on-site control box, with an emergency stop button.

Centralized Control Host (CA-PSKD/JZKP): Software management system integrating CAN bus communication, video display (real-time on-site images), and unified device control. Select monitors by address for remote operation.

3.2.2 Key Operations

A/B Point Self-Swing: On the on-site control box, select the swing direction → press "A" → move to the desired swing end → press "B" → the monitor swings back and forth between A and B. Cancel by pressing any swing direction key.

Mode Switching: Use the control box/remote controller to switch between DC columnar (long-distance) and foggy (wide coverage) spray modes based on fire conditions.

Video Monitoring (Optional): Access real-time images via the centralized control host; capture and store on-site scenes for post-fire analysis.

3.3 Maintenance Tips

Mechanical Maintenance: Inject lubricating grease into transmission components (worm/worm gear) periodically to ensure flexible rotation; check for blockages in the nozzle if pressure is abnormal or range is reduced.

Electrical Maintenance: Regularly inspect wiring connections (CAN bus, power cables, video cables) for looseness or damage; clean the camera lens (if equipped) to maintain clear images.

Environmental Protection: For outdoor use, protect the control box and remote controller from extreme humidity; apply anti-corrosion treatment to the monitor surface for long-term service.

Function Test: Conduct monthly functional tests (control mode switching, spray mode conversion, A/B point swing) to verify system reliability.

3.4 Precautions

Do not stand in front of the nozzle during operation to avoid high-pressure spray impact accidents.

Ensure the installation base and anti-sway bracket are firmly fixed to withstand recoil and transmission force.

Use only compatible media (water, aqueous film-forming foam); avoid corrosive substances that may damage internal components.

When using wireless control, ensure no strong electromagnetic interference in the area to maintain signal stability.

4. Packaging & Transportation

Our PSKD-CA/BU Series Electrically Controlled Fire Monitors are packaged in export-grade wooden crates with shock-absorbing foam to protect the monitor main body, control components, and optional camera. This packaging ensures stability during transit, prevents damage from handling or impact, and guarantees the product arrives in pristine condition with intact functionality.

5. Application Scenarios

Industrial & Mining: Coal yards, mining facilities, and large-scale industrial workshops.

Petrochemical Industry: Refineries, oil storage areas, and chemical processing plants.

Transportation & Logistics: Ports, terminals, and freight warehouses.

Specialized Facilities: Large-scale warehouses, power plants, and offshore oil support bases.

Public & Commercial: High-risk industrial parks and large logistics centers.

6. Frequently Asked Questions (FAQ)

Q: What control modes does this monitor support?A: It has three control modes: on-site manual control (control box), remote wired control (CAN bus, ≥200m), and wireless remote control (150m)-adapting to different operation distances.

Q: Can it automatically cover a specific area?A: Yes. The A/B point self-swing function allows setting a swing range between two points, enabling automatic cyclic coverage of large areas without manual operation.

Q: Is video monitoring available?A: Video function is optional. Equipped with a camera, it transmits real-time on-site images to the centralized control host for remote observation and image storage.

Q: What installation modes are available?A: Standard seated installation; hanging installation is optional but requires advance communication with the manufacturer to confirm structural details.

Q: What is the maximum wired control distance?A: The wired control distance is ≥200m via CAN bus communication. For distances exceeding 100m, video signals require switches or fiber optic transmission.

7. Product Comparison (vs. Competitors & Standard Electric Monitors)

Key Comparison Points CA-FIRE PSKD-CA/BU Series Competitor Electric Monitor CA-FIRE Standard PSKD Series
International Certifications CCC + CE + GB19156/GB19157 CE Only CCC + CE + GB19156
Control Modes 3 (On-site + Wired + Wireless) 2 (On-site + Wired) 2 (On-site + Remote)
Rotation Range 360° + (-85°~+85°) 350° + (-60°~+60°) 350° + (-15°~+60°)
Intelligent Functions A/B point self-swing + Optional video No self-swing + No video No self-swing + Optional video
Control Distance Wired:≥200m; Wireless:150m Wired:≤150m; Wireless:100m Wired:≤180m; Wireless:120m
Transmission Mode Worm & Worm Gear (self-locking) Gear Transmission (no self-locking) Worm Gear (self-locking)
Annual Maintenance Cost $35/Unit $55/Unit $30/Unit
After-Sales Warranty 2 Years + Electrical Component Guarantee 1 Year 2 Years

8. Contact: Dulcia

Email: sales8@ca-fire.com

Tel/WhatsApp: +86 191 6381 1547

WeChat: Dulcia8