
CA-FIRE ZDMS Intelligent Auto-Tracking Positioning Jet Fire Extinguisher
CA-FIRE ZDMS Intelligent Auto-Tracking Positioning Jet Fire Extinguisher Product Introduction For ZDMS Series Auto-Tracking Positioning Jet Device (Model: ZDMS0.6 5S/10S; Control Box: ZDMAN-NX; Central Control Cabinet: ZDM-ZK01) 0. Company Introduction CA-FIRE Fire Protection Co., LTD,...
Description
Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of ca-fire zdms intelligent auto-tracking positioning jet fire extinguisher in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.
CA-FIRE ZDMS Intelligent Auto-Tracking Positioning Jet Fire Extinguisher Product Introduction
For ZDMS Series Auto-Tracking Positioning Jet Device (Model: ZDMS0.6 5S/10S; Control Box: ZDMAN-NX; Central Control Cabinet: ZDM-ZK01)
0. Company Introduction
CA-FIRE Fire Protection Co., LTD, established in 2012 and rooted in Quanzhou, China, focuses on the research, development, and production of high-performance firefighting equipment. Our product lineup includes FM-approved fire sprinklers, hydrants, alarm valves, foam systems, and CCC/CE-certified nozzles. We strive to deliver trustworthy, long-lasting, and compliant fire safety solutions for residential, commercial, and industrial clients worldwide.CA-FIRE's product range covers diverse fire protection needs: Fire Sprinklers; Indoor & Outdoor Fire Hydrants; Alarm Valves (Wet/Deluge/Explosion-Proof); Foam Systems (Bladder Tanks, Generators); Fire Nozzles, Water Monitors & Hoses; Hose Reels, Couplings & Accessories; and Intelligent Jet Fire Extinguishing Equipment. Every product undergoes stringent quality control and adheres to global fire safety standards, with tailor-made solutions available for specific project demands.
1. Product Overview & Core Advantages
1.1 Product Overview
The ZDMS Series Auto-Tracking Positioning Jet Fire Extinguisher is a state-of-the-art intelligent fire suppression core, integrating flame detection, automatic tracking, precise targeting, and focused jet functions. It forms a complete intelligent fire protection system with on-site control boxes (ZDMAN-NX), central control cabinets (ZDM-ZK01), solenoid valves, fire pumps, and alarm systems. Engineered for large-span, high-ceiling spaces, it adopts a two-stage sensing system (ultraviolet flame detector + infrared positioning sensor) to automatically scan protected areas. Upon fire detection, it rapidly locks onto the fire source, adjusts the jet angle, and activates the valve to spray water for efficient fire suppression. Supporting CAN bus and Ethernet communication, it enables remote monitoring and manual control via the central control system, ensuring swift response in large-scale environments.
1.2 Core Advantages
Two-Stage Sensing & Precision Targeting: Combines ultraviolet flame detection for fast fire recognition and infrared positioning for high-accuracy targeting; supports on-site calibration to refine jet precision.
Four Versatile Installation Modes: Wall/column mounting, overhead suspension, ceiling extension, and terminal installation-adapting to varied large-space layouts (warehouses, stadiums, exhibition halls).
Dual-Communication Remote Control: On-site CAN bus and remote Ethernet connectivity enable centralized management, video surveillance, and remote operation via the ZDM-ZK01 central control cabinet, boosting operational efficiency.
Rugged Environmental Adaptability: Features waterproof, dustproof, and impact-resistant design; detection components are shielded from debris blockage, ensuring stable performance in harsh industrial settings.
Seamless System Integration: Works seamlessly with fire pumps, alarm systems, and signal valves; supports multi-device networking via daisy-chain CAN bus wiring for wide-area coverage.
Adjustable Sensitivity & Parameter Tuning: Sensor sensitivity can be customized to on-site conditions, preventing false activation from open flame construction, high-temperature equipment, or strong light sources.
2. Technical Specifications
2.1 Core Device Parameters
| Parameter Category | Details |
|---|---|
| Model | ZDMS0.6 5S/10S |
| On-Site Control Box | Model: ZDMAN-NX; Operating Voltage: 220VAC 50Hz; Dimensions: 250×180×80mm; Installation Height: 1.5m above ground |
| Central Control Cabinet | Model: ZDM-ZK01; Operating Voltage: 220VAC 50Hz; Dimensions: 650×580×1400mm; Installation: Floor-standing in fire control room |
| Communication Protocol | On-site: CAN bus; Remote: Ethernet |
| Detection Coverage | 360° unobstructed coverage (no obstacles allowed in protected areas) |
| Power-On Reset Angle | Monitor head resets to 65° |
| Indicator Status | Normal Operation: Intermittent flash (long off + short on); Fault: Slow flash (long on + short off); Positioning Jet: High-frequency flash; Scanning: Steady on |
| Pipeline Pressure Requirement | Complies with device performance standards; pressure stabilizing device required (minimal pressure fluctuation) |
2.2 Cable Specification Requirements
| Cable Type | Specification | Application |
|---|---|---|
| Communication Signal Cable | NH-RVSP2×1.0mm² (twisted pair); NH-RVSP2×1.5mm² (CAN bus) | Control box ↔ Device; Multi-device networking |
| Power Cable | NH-RVV3×1mm² (device power); NH-RVV3×2.5mm² (control box power) | Control box ↔ Device; Central control ↔ Control box |
| Valve Connection Cable | NH-RVV2×1mm² | Control box ↔ Solenoid valve (V1, V2) |
| Feedback Signal Cable | NH-RVV2×1mm² | Water flow indicator/signal valve ↔ Control box |
| Ethernet Cable | NH-UTP-CAT5 (T-568B standard) | Central control ↔ Camera/Control box (max length ≤100m) |
2.3 Power Supply Capacity (Copper Power Cable)
| Cable Cross-Section | Safe Current-Carrying Capacity | Maximum Manageable Devices |
|---|---|---|
| 1.0mm² | 17A | 20 |
| 1.5mm² | 21A | 38 |
| 2.5mm² | 28A | 50 |
| 4.0mm² | 35A | 65 |
| 6.0mm² | 48A | 120 |
2.4 Certifications
CCC, CE
3. Installation, Debugging & Maintenance Guidelines
3.1 Installation Requirements
Pre-Installation Checks: Install the device only after pipeline installation, flushing, and pressure testing are completed; store properly with dust, moisture, and corrosion protection before installation.
Protected Area Requirement: No obstacles blocking detection, positioning, or jetting; 360° unobstructed view for wall-mounted devices (limit mark facing the wall).
Load-Bearing & Stability: Verify the pipe network's load-bearing capacity; reinforce supports if necessary to avoid shaking during jetting (ensures positioning accuracy).
Installation Details:
Handle gently to avoid impact; do not strike control or detection components, and never wipe sensor light-receiving surfaces by hand.
Keep the upper flange end face horizontal to ensure the device body is vertically downward.
Adjust the large-space flame detector to face downward after installation.
Thoroughly clean pipelines before installing electric valves; install a filter upstream to prevent blockage.
Environmental Protection: Implement waterproof, dustproof, and impact-resistant measures after installation.
3.2 Installation Modes
Wall/Column Mounting: Limit mark faces the wall; maintain a distance of ≥350mm from obstacles.
Overhead Suspension: Directly suspend on the pipe network; ensure secure fixation.
Ceiling Extension: Extend from the ceiling via connecting pipes; align with the center of the protected area.
Terminal Installation: Install at pipeline terminals; compatible with DN50~DN32 pipe diameters.
3.3 Debugging Procedures
Initial Power-Up Verification: Confirm correct wiring, power on the central control cabinet and control box; the device resets to 65° with intermittent flashing indicators (normal operation). Troubleshoot loose connections or foreign object jams if abnormal (slow flashing = fault).
Address Registration: The device automatically registers with the control box; verify displayed address, configuration parameters, and model information. Double-click "Reset" for duplicate addresses and re-register.
Channel Configuration: Use the central control mouse to access the "Channel Management" page, search for cameras, and add them to corresponding channels (set device adding mode to "Manual").
Functional Testing: Conduct on-site ignition tests to verify scanning, positioning, valve activation, and jetting performance.
Parameter Calibration:
Adjust sensor sensitivity based on on-site conditions to avoid false activation.
Calibrate jet position if water drop point deviates: Enter debugging mode via the control box, use arrow keys to align the jet with the fire source, and exit to save parameters.
Fine-tune installation height parameters for minor deviations (e.g., set 10m actual height to 12m).
3.4 Maintenance Recommendations
Monthly Inspections: Clean sensors (avoid direct contact), inspect cables for damage, and verify indicator status and communication stability.
Pipeline Maintenance: Ensure pipeline pressure meets requirements; regularly check pressure stabilizing devices to avoid large fluctuations.
Interference Handling: If frequent false activation occurs, adjust sensor sensitivity or temporarily power off the device (consult after-sales first).
Wiring Maintenance: Inspect CAN bus daisy-chain wiring and cable markings; never mix power and communication cables.
System Updates: Coordinate with after-sales for central control software and firmware updates to optimize performance.
4. Packaging & Transportation
Our ZDMS Intelligent Jet Devices are packaged in export-grade wooden crates with shock-absorbing materials to protect sensitive components (sensors, control modules). This packaging ensures stability during transit, prevents damage from handling, and guarantees products arrive in pristine condition with intact functionality.
5. Application Scenarios
Industrial Facilities: Large warehouses, logistics centers, industrial workshops, and high-bay factories.
Commercial & Public Spaces: Stadiums, exhibition centers, convention halls, shopping malls, and airport terminals.
Specialized Buildings: Gymnasiums, theaters, libraries, and large-scale office complexes.
Infrastructure: Subway stations, railway stations, and large parking garages.
Other Large Spaces: High-ceilinged retail stores, entertainment venues, and assembly plants.
6. Frequently Asked Questions (FAQ)
Q: What installation modes are supported by this device?A: It offers four modes: wall/column mounting, overhead suspension, ceiling extension, and terminal installation-adapting to diverse large-space layouts.
Q: How to resolve communication failures between the device and control box?A: Check if the CAN bus uses NH-RVSP2×1.5mm² twisted pair, wiring is daisy-chained, H/L terminals are not reversed, and there are no loose connections or cable damage.
Q: Can the jet position be adjusted if it deviates from the fire source?A: Yes. Enter debugging mode via the control box, use arrow keys to align the jet with the fire source, and exit to save calibration parameters. Minor deviations can also be fixed by adjusting installation height parameters.
Q: How many devices can one central control cabinet manage?A: It depends on the power cable cross-section: 20 devices with 1.0mm² cables, 50 with 2.5mm², and 120 with 6.0mm².
Q: How to connect the optional camera to the central control system?A: Use NH-UTP-CAT5 cables (T-568B standard) to connect the camera to the central control cabinet; for distances exceeding 100m, use switches or fiber optic transmission.
7. Product Comparison (vs. Competitors)
| Key Comparison Points | CA-FIRE ZDMS Series | Competitor A | Competitor B |
|---|---|---|---|
| International Certifications | CCC + CE | CE Only | No Major Certifications |
| Positioning Accuracy | High (supports on-site calibration) | Medium (no calibration function) | Low (fixed parameters) |
| Communication Modes | CAN Bus + Ethernet | CAN Bus Only | Wired Only |
| Installation Flexibility | 4 Modes | 2 Modes | 1 Mode |
| Control Functions | Remote Monitoring + Video Linkage + Manual Control | Remote Control Only | Local Control Only |
| Sensor Sensitivity | Adjustable (anti-interference) | Fixed (prone to false activation) | Fixed (poor adaptability) |
| Multi-Device Networking | Daisy-Chain CAN Bus (Unlimited Quantity) | Limited to 10 Devices | No Networking Function |
| Annual Maintenance Cost | $50/Unit | $80/Unit | $65/Unit |
| After-Sales Warranty | 2 Years + Technical Support | 1 Year | No Warranty |
| FOB Port Price | $XX/Unit | $XX+150/Unit | $XX-100/Unit (No Intelligent Positioning) |
8. Contact: Dulcia
Email: sales8@ca-fire.com
Tel/WhatsApp: +86 191 6381 1547
WeChat: Dulcia8
Hot Tags: ca-fire zdms intelligent auto-tracking positioning jet fire extinguisher, China ca-fire zdms intelligent auto-tracking positioning jet fire extinguisher manufacturers, suppliers, factory
Send Inquiry
You Might Also Like






