SNSS65 Double Outlet Indoor Fire Hydrant is a reliable fire protection device designed for building fire systems. It provides stable water supply through dual outlets, allowing fast hose connection and efficient firefighting in commercial, industrial, and public facilities.

Description

Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of snss65 double outlet indoor fire hydrant in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.

 

 

Products Description

 
product-800-800
 
 

SNSS65 Double Outlet Indoor Fire Hydrant

The SNSS65 Indoor Fire Hydrant is a dual-valve, dual-outlet fire suppression water supply unit engineered for interior fire protection networks across commercial, industrial, and public facilities. It delivers dependable water flow for firefighting missions via hose and nozzle assemblies housed within hydrant enclosures.

Produced in compliance with the GB3445-2018 Indoor Fire Hydrant Standard, the SNSS65 guarantees consistent functionality, secure handling, and effective water dispersion during critical fire emergencies.

1

Working Principle

 

The SNSS65 indoor fire hydrant interfaces with the building's pressurized fire water distribution network. Upon activation during an emergency, the valve is engaged manually via the hydrant handwheel.

Water is drawn from the primary pipeline into the hydrant chamber, then routed through either a single outlet or both outlets concurrently, enabling emergency responders to attach hoses for immediate fire control.

The dual-outlet configuration supports parallel operation, significantly enhancing operational efficiency when addressing extensive fire incidents.

 

2

Technical Specifications

 

Item Specification
Model SNSS65
Type Double outlet indoor fire hydrant
Nominal Diameter DN65
Working Pressure 1.6 MPa
Test Pressure 2.4 MPa
Inlet Connection Rp 2 1/2"
Outlet Type Double outlet
Applicable Medium Water / Foam mixture
Standard GB3445-2018

 

3

Installation Guidelines

 

 

 

 

 

product-800-800

product-800-800

Correct mounting of the SNSS65 Indoor Fire Hydrant is critical to guaranteeing dependable functionality under emergency circumstances. The unit must be housed within an approved hydrant enclosure and linked to a consistent fire suppression water source.

Primary installation guidelines:

Mount onto a reinforced pipe run with adequate structural bracing

Verify that the intake orientation aligns with the system's flow path

Position the valve control so it remains readily reachable from within the cabinet

Conduct hydrostatic testing following completion of the setup

Confirm that hose couplings conform to applicable interface standards

All mounting procedures should adhere to regional fire safety regulations and the project's engineered system plans.

 

4

Maintenance & Inspection

product-800-800
 

Regular inspection and maintenance help ensure long-term reliability of the fire hydrant system.

Recommended maintenance practices include:

Monthly visual inspection for leakage or corrosion

Regular valve opening/closing test to ensure smooth operation

Check sealing components for wear or damage

Ensure no obstruction inside hydrant cabinet

Annual pressure testing according to fire safety regulations

Proper maintenance ensures the hydrant remains ready for emergency use at all times.

 

4

FAQ

FAQ

Q: What is an SNSS65 indoor fire hydrant used for?

A: The SNSS65 indoor fire hydrant is used in building fire protection systems to provide a reliable water supply for firefighting. It is installed inside hydrant cabinets and allows firefighters to connect hoses for emergency fire suppression.

Q: What does "double outlet" mean in SNSS65 hydrant?

A: Double outlet means the hydrant is equipped with two water discharge ports. This allows two fire hoses to be connected and used at the same time, improving firefighting efficiency in large buildings or high-risk areas.

Q: What is the standard working pressure of SNSS65?

A: The typical working pressure is 1.6 MPa, with a test pressure of 2.4 MPa. It can be customized based on project requirements and system design conditions.

Q: Where is SNSS65 indoor fire hydrant commonly installed?

A: It is widely installed in commercial buildings, warehouses, factories, hotels, hospitals, schools, and other indoor fire protection systems that require fixed water supply points.

Q: What standards does SNSS65 comply with?

A: The SNSS65 indoor fire hydrant is generally manufactured in accordance with GB3445-2018 standard and can be adapted to different international connection standards such as BS, ANSI, and GB systems.