CA-FIRE 6” Dry Type Fire Hydrant Product
CA-FIRE 6" Dry Type Fire Hydrant Product Introduction For 6" Dry Type Underground/Above-Ground Fire Hydrant 0. Company Introduction CA-FIRE Fire Protection Co., LTD, founded in 2012 and located in Quanzhou, China, specializes in the R&D, manufacturing, and supply of high-quality firefighting...
Description
Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of ca-fire 6” dry type fire hydrant product in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.
CA-FIRE 6" Dry Type Fire Hydrant Product Introduction
For 6" Dry Type Underground/Above-Ground Fire Hydrant
0. Company Introduction
CA-FIRE Fire Protection Co., LTD, founded in 2012 and located in Quanzhou, China, specializes in the R&D, manufacturing, and supply of high-quality firefighting equipment. Our product portfolio covers FM-certified fire sprinklers, dry/wet type fire hydrants, alarm valves, foam systems, CCC/CE-certified nozzles, and CCCF-certified lined fire hoses. We adhere to strict enterprise standards and international quality norms, delivering reliable fire protection solutions for residential, commercial, industrial, and municipal projects worldwide-especially in cold regions requiring anti-freeze performance.
CA-FIRE's product range caters to diverse fire safety needs, including Fire Sprinklers & Accessories; Dry/Wet Type Fire Hydrants (underground/above-ground); Alarm Valves (Wet/Deluge/Explosion-Proof Types); Foam Extinguishing Systems; Fire Nozzles, Water Monitors & Hoses; and Lined Fire Hoses. All products undergo rigorous factory testing and inspection, ensuring compliance with local regulations and project acceptance requirements.
1. Product Overview & Core Advantages
1.1 Product Overview
The 6" Dry Type Fire Hydrant is a specialized anti-freeze fire control device designed for cold climates, featuring a dry internal structure that avoids standing water-effectively preventing freezing and bursting in low temperatures. It is a reliable emergency water supply tool with convenient, flexible, and reliable operation, suitable for underground/above-ground installation in municipal roads, industrial parks, commercial districts, and residential communities in cold regions.
Key design features include: a split structure (upper/lower body) for easy maintenance; EPDM seals for leak-proof performance; galvanized standard parts for anti-corrosion; and a dedicated drainage system that keeps the internal cavity dry when closed. The hydrant's assembly flange is compatible with 4" outlets, ensuring flexible connection with fire hoses and fire trucks. With a working pressure of 16.5MPa and test pressure of 22.5MPa, it meets high-pressure emergency water supply demands.
1.2 Core Advantages
Anti-Freeze Dry Structure: No standing water inside the valve cavity when closed, eliminating freezing and bursting risks in low-temperature environments (suitable for ≤-20℃ regions).
High Pressure Bearing Capacity: Working pressure 16.5MPa, test pressure 22.5MPa-far exceeding basic emergency requirements, ensuring structural integrity under extreme conditions.
Reliable Sealing Performance: Adopts high-quality EPDM seals at key joints, with good oil resistance and aging resistance, ensuring long-term leak-proof operation.
Convenient Operation & Maintenance: Split upper/lower body design, turbine-driven valve stem, and dedicated wrench for flexible operation; standardized parts for easy replacement.
Corrosion-Resistant Materials: Galvanized bolts/nuts, steel connecting pipes, and brass (59-1) joints-resisting corrosion from soil, moisture, and industrial environments.
Drainage Guarantee: Drainage outlet is unobstructed when closed, quickly removing residual water to maintain internal dryness.
Flange Compatibility: Assembly flange matches 4" outlets, compatible with standard fire hoses and fire truck connections.
2. Technical Specifications
| Specification Category | Details |
|---|---|
| Model | 6" Dry Type Fire Hydrant |
| Type | Underground/Above-Ground Dry Type |
| Working Pressure | 16.5MPa |
| Test Pressure | 22.5MPa |
| Main Material | Upper/Lower Body: Steel; Seals: EPDM; Joints: Brass (59-1); Fasteners: Galvanized Steel |
| Surface Coating | Underground Part: Black Paint; Above-Ground Part: Red Paint |
| Flange Compatibility | Assembly flange matches 4" outlet (standard connection) |
| Drainage Requirement | Drainage outlet unobstructed when closed, no blockage |
| Operation Mode | Turbine-driven valve stem + dedicated wrench |
| Key Components | Gland, turbine assembly, large cap rubber pad, sealing rings, connecting pipe stem, fixed foot, top cover |
| Installation Type | Underground/Above-Ground (customizable based on project needs) |
| Working Temperature | ≤-20℃ (anti-freeze design) |
| Certifications | CE, Enterprise Standard Compliant |
3. Installation, Operation & Maintenance Guidelines
3.1 Installation Requirements
Foundation Preparation: Install on a reinforced concrete foundation (≥C25 strength) with embedded fixed feet to ensure stability under water pressure and impact.
Flange Connection: Align the assembly flange with the pipeline flange; use EPDM gaskets and torque galvanized bolts evenly to avoid leakage.
Drainage System Check: Ensure the drainage outlet is unobstructed and connected to the municipal drainage network to prevent residual water accumulation.
Cold Climate Installation: For regions with ≤-30℃ temperatures, add a thermal insulation sleeve to the above-ground part and wrap the underground pipeline with anti-freeze material.
Sealing Treatment: Use sealant for threaded connections to enhance leak-proof performance; avoid damaging the surface paint during installation.
3.2 Operation Instructions
Pre-Use Inspection: Remove the top cover, check the drainage outlet for blockage, confirm the turbine and valve stem operate flexibly, and verify no debris in the valve cavity.
Valve Opening: Insert the dedicated wrench into the turbine assembly, rotate clockwise to open the valve-water flows into the cavity and is discharged through the 4" outlet; adjust the opening degree to control flow rate.
Connection & Fire Suppression: Connect fire hoses or fire truck suction pipes to the 4" outlet; ensure tight connections to avoid leakage during high-pressure water supply.
Post-Use Shutdown: Rotate the wrench counterclockwise to close the valve tightly; confirm the drainage outlet is unobstructed to drain residual water, then reattach the top cover.
3.3 Maintenance Tips
Quarterly Inspection: Check the surface paint for peeling (touch up promptly), verify the drainage outlet is unblocked, and ensure the valve stem operates smoothly.
Semi-Annual Lubrication: Apply anti-rust grease to the turbine assembly and valve stem to prevent seizing in cold weather.
Annual Pressure Test: Conduct a 22.5MPa hydrostatic test to confirm no leakage in the body, flanges, and seals.
Winter Preparations: Before freezing temperatures, fully drain residual water and inspect the drainage system for blockages; replace aged EPDM seals if needed.
Corrosion Protection: For coastal or industrial areas, apply anti-corrosion coating to the above-ground part every 1-2 years.
4. Packaging & Transportation
Packaging: Each 6" Dry Type Fire Hydrant is wrapped in PE film and foam padding to protect the body and components from scratches. Accessories (wrench, gaskets, bolts) are packed in a separate carton. Multiple units are loaded into export-grade wooden crates with reinforced corners for sea/air freight.
Transportation: Avoid stacking heavy loads on crates; protect from rain, impact, and mechanical damage during transit. Store in a dry, ventilated warehouse (temperature: -10℃~40℃) for up to 12 months.
5. Application Scenarios
Cold Region Municipal Infrastructure: Urban roads, residential communities, parks, and public squares in northern China, high-altitude areas, and cold countries.
Industrial Zones in Cold Climates: Factories, petrochemical parks, logistics warehouses, and power plants in low-temperature industrial areas.
Commercial Districts & Public Facilities: Shopping malls, hotel clusters, hospitals, schools, and stadiums in cold regions.
Transport Hubs: Railway stations, highway service areas, and ports in freezing climates.
6. Frequently Asked Questions (FAQ)
Q: What is the difference between dry type and wet type fire hydrants?A: Dry type hydrants have no standing water in the cavity when closed, suitable for cold regions to prevent freezing; wet type hydrants are filled with water, suitable for warm regions with ≥0℃ temperatures.
Q: Why is the drainage outlet important for this hydrant?A: The drainage outlet quickly removes residual water after shutdown, keeping the cavity dry-this is the core anti-freeze design to avoid freezing and bursting.
Q: What is the maximum low temperature this hydrant can withstand?A: It is designed for ≤-20℃ environments; for ≤-30℃, add a thermal insulation sleeve and enhance anti-freeze measures for the pipeline.
Q: Can the hydrant be installed both underground and above-ground?A: Yes. It supports both installation types-underground for municipal roads (only the top cover exposed) and above-ground for industrial zones (full body exposed with anti-freeze treatment).
Q: What materials are the seals made of?A: The seals are EPDM, which has excellent oil resistance, aging resistance, and low-temperature flexibility-ensuring leak-proof performance in cold climates.
7. Product Comparison (vs. Competitors & Wet Type Hydrants)
| Comparison Item | CA-FIRE 6" Dry Type Fire Hydrant | Competitor Dry Type Hydrant | Wet Type Fire Hydrant |
|---|---|---|---|
| Working Pressure | 16.5MPa | 12MPa | 1.6~10MPa |
| Test Pressure | 22.5MPa | 18MPa | 2.4~15MPa |
| Anti-Freeze Performance | ≤-20℃ (dry cavity) | ≤-15℃ | Not applicable (≥0℃) |
| Seal Material | EPDM (high quality) | Ordinary rubber | Ordinary rubber |
| Fastener Treatment | Galvanized (anti-corrosion) | No anti-corrosion treatment | Galvanized (partial) |
| Drainage Design | Unobstructed dedicated outlet | Simple drainage (prone to blockage) | No drainage system |
| Maintenance Frequency | Quarterly | Monthly | Semi-Annual |
| Service Life (Cold Regions) | 8~10 years | 5~6 years | 3~4 years (prone to freezing damage) |
| After-Sales Warranty | 2 years (parts + labor) | 1 year (parts only) | 1 year (parts only) |
8. Contact: Dulcia
Email: sales8@ca-fire.com
Tel/WhatsApp: +86 191 6381 1547
WeChat: Dulcia8
Hot Tags: ca-fire 6” dry type fire hydrant product, China ca-fire 6” dry type fire hydrant product manufacturers, suppliers, factory
Send Inquiry
You Might Also Like