Pre Action Alarm Valve
video
Pre Action Alarm Valve

Pre Action Alarm Valve

Pre Action Alarm Valve
The pre action alarm valve of the pre-acting system is composed of the deluge valve and the wet alarm valve. The deluge valve is located on the water supply side, and the wet alarm valve is located on the system side and becomes the pre-acting valve group.
The system is composed of pre-action valve, hydraulic alarm bell, pressure switch, air compressor, air maintenance installation, signal disc valve, etc. The closed sprinkler is installed, and the commonly used detection system is used as the alarm and start device.

Description

Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of pre action alarm valve in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.

 

Pre Action Alarm Valve

 

The pre action alarm valve of the pre-acting system is composed of the deluge valve and the wet alarm valve. The deluge valve is located on the water supply side, and the wet alarm valve is located on the system side and becomes the pre-acting valve group.

 

The system is composed of pre-action valve, hydraulic alarm bell, pressure switch, air compressor, air maintenance installation, signal disc valve, etc. The closed sprinkler is installed, and the commonly used detection system is used as the alarm and start device.

 

The Working Principle

 

Once a fire occurs, the fire detector installed in the protected area sends out fire alarms and other signals. Fire alarm controller or fire control center, after receiving the alarm signal, issue an instruction to open the solenoid valve on the rain shower valve, so that the rain shower valve is opened, the pressure water flow into the system side pipe network, into the wet sprinkler system, while the hydraulic alarm bell issued a warning, the pressure switch action feedback to the control center to show that the pipeline has been filled with water, and start the fire pump. At this time, the closed sprinkler installed on the pipeline has not been released and will not spray water. People can still take the initiative to take appropriate actions by the competent personnel to extinguish the fire and avoid the loss caused by the water damage caused by the sprinkler operation. If the fire cannot be controlled and continues to develop, the closed sprinkler glass ball will spray water and the pump will start automatically.

 

What Is Alarm Valve

 

FAQ

 

Q1. Can I have a sample order?
A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.

Q2. What about the lead time?
A:Sample needs 7-15 days, mass production time needs 30-40 weeks for order quantity more than 1 container.

Q3. Do you have any MOQ limit?
A: For conventional products, Low MOQ, OEM products request 30-40days.

Q4. How do you deliver the goods and how long does it take to arrive?
A: We usually deliver mass order by sea and air, delivery time is depended on the carrier,urgent trail order usually deliver by
DHL, UPS, FedEx or TNT. It usually takes 3-5 days to arrive. Railway also optional.

Q5. What is your term and payment?
A: Payment<=1000USD, 100% in advance. Payment>=1000USD, 30% T/T in advance ,balance before shippment.

Q6. Is it OK to OEM ?
A: Yes. Please inform us formally before our production and confirm the design and other requirements firstly .

Q7: Do you offer guarantee for the products?
A: Yes, we offer 1 year warranty to our products.

Hot Tags: pre action alarm valve, China pre action alarm valve manufacturers, suppliers, factory

You Might Also Like

Shopping Bags