
Fire Protection Bottom Valve Foot Valve
A fire protection bottom valve is a special check valve installed at the bottom end of the suction pipe of a fire pump. It has the dual functions of **filtering impurities** and **one-way water stoppage**. Compared with ordinary industrial bottom valves.
Description
Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of fire protection bottom valve foot valve in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.
Products Description

CA-FIRE Fire Protection Foot Valve
A fire protection bottom valve is a special check valve installed at the bottom end of the suction pipe of a fire pump. It has the dual functions of **filtering impurities** and **one-way water stoppage**. Compared with ordinary industrial bottom valves, it has made three core optimizations for fire protection scenarios:
- **Large-flow filter design**: A perforated stainless steel filter is used, with a perforation rate 20% higher than that of industrial bottom valves. It filters impurities while reducing water head loss, meeting the large-flow suction requirements of fire pumps;
- **Self-suction sealing structure**: The valve disc adopts a heavy hammer design, which can quickly seal within 1-2 seconds after the pump stops, preventing water from flowing back in the suction pipe and maintaining the vacuum state inside the pipe, ensuring that the pump does not need to be refilled with water when restarted;
- **Corrosion-resistant and wear-resistant materials**: The valve body is made of ductile iron and coated with epoxy anti-rust paint, and the filter is made of 304 stainless steel. It can operate stably in the damp and corrosive environment of the fire water tank for a long time, with a service life 3-5 years longer than that of industrial bottom valves.
| DN | L | D | D1 | D2 | Bolt Holes (n–Ø) |
|---|---|---|---|---|---|
| 50 | 164 | 165 | 125 | 99 | 4 × Ø19 |
| 65 | 217 | 185 | 145 | 118 | 4 × Ø19 |
| 80 | 240 | 200 | 160 | 132 | 8 × Ø19 |
| 100 | 275 | 220 | 180 | 152 | 8 × Ø19 |
| 125 | 307 | 250 | 210 | 184 | 8 × Ø19 |
| 150 | 343 | 285 | 240 | 211 | 8 × Ø23 |
| 200 | 470 | 340 | 295 | 266 | 8 × Ø23 / 12 × Ø23 |
| 250 | 600 | 405 | 355 | 319 | 12 × Ø23 / 12 × Ø28 |
| 300 | 720 | 460 | 410 | 370 | 12 × Ø23 / 12 × Ø28 |
The "Underwater Foundation" of Fire Safety: Irreplaceable Practical Value
### 1. Secure the "3-Minute Golden Firefighting Window"
The first 3 minutes after a fire occurs is the critical window for initial firefighting. If the fire pump needs to be manually filled with water for venting when it starts, it often delays by 1-2 minutes, leading to the fire getting out of control. The self-suction sealing function of the fire bottom valve enables the pump to start without filling water, directly establishing a stable suction pressure, ensuring that the water gun and sprinkler system receive sufficient water supply at the first moment.
### 2. Protect the fire pump from damage
The fire pump is the core equipment of the fire water supply system. If impurities enter the impeller, it will cause wear and increased vibration of the impeller, and even burnout of the pump body. The filter screen of the bottom valve can effectively intercept over 90% of solid impurities, reducing the risk of pump failure and ensuring the continuous and stable operation of the pump during fire fighting.
### 3. Emergency Water Supply Adapted to Complex Water Sources
In scenarios where natural water sources (rivers, lakes) are used as backup water sources, there are more impurities such as sediment and aquatic plants in the water. The high-maintenance filter screen of the fire-fighting bottom valve can effectively deal with such complex water quality, ensuring that the water pump can normally draw water and preventing water supply interruption due to water source impurities.
4. Maintain pipe network vacuum and enhance system redundancy
When the fire protection system adopts a temporary high-pressure water supply method, the sealing performance of the bottom valve after the pump is stopped can maintain the vacuum state in the suction pipe, preventing air from entering the pipe. This not only shortens the response time for the next startup but also reduces the cavitation damage to the water pump and extends the service life of the equipment.

Safety Guidelines for Installation and Maintenance
### Installation Requirements
- **Submersion Depth**: The bottom valve must be submerged at least 0.5 meters underwater, and the filter screen should be at least 0.3 meters away from the bottom of the water tank to prevent the inhalation of sediment from the bottom of the tank;
- **Vertical Installation**: The bottom valve should be installed vertically at the bottom end of the suction pipe to ensure that the valve flap can fully close under its own weight;
- **Filter Screen Orientation**: The perforated surface of the filter screen should face the direction of the water flow to avoid the accumulation of impurities on the back of the filter screen.
### Daily Maintenance
- **Monthly Inspection**: Open the manhole of the water tank, observe whether there are any debris accumulated on the surface of the filter screen, and gently shake the bottom valve to listen for any stuck or abnormal sounds;
- **Quarterly Cleaning**: Disassemble the filter screen, remove the accumulated mud, debris, and check if the filter screen is damaged. Replace it in time if necessary;
- **Annual Pressure Test**: Conduct a water pressure sealing test at 1.5 times the working pressure on the bottom valve to check the sealing performance of the valve disc and ensure there is no leakage.
### Common Misconceptions
- Misconception 1: **Not Cleaning the Filter When It Gets Clogged**: Failure to clean it over time will result in insufficient flow and a decrease in the water pressure of the pump;
- Misconception 2: **Insufficient Installation Depth**: Inhaling air will cause the pump to suffer from cavitation, reducing efficiency and even damaging the pump body;
- Misconception 3: **Using Ordinary Industrial Bottom Valves Instead**: The flow design and sealing performance of industrial bottom valves cannot meet the high requirements of fire-fighting scenarios, and they are prone to causing malfunctions.
Underwater Firefighting Lifeline: The Safety Logic and Practical Value of Fire Bottom Valves
In a fire incident at a warehouse logistics park in 2024, the firefighters arrived at the scene and activated the fire pump, only to find that the water pressure from the pump remained consistently low. After investigation, it was discovered that the filter screen at the bottom of the suction pipe of the pump was completely blocked by fallen leaves and sediment in the water pool, resulting in insufficient water intake and delaying the initial firefighting opportunity. This hidden "invisible valve" beneath the water is precisely an easily overlooked but crucial part of the fire water supply system.
Our address
NO.8, YUANFENG ROAD, MEIYUAN VILLAGE, KANGMEI TOWN, NANAN CITY, QUANZHOU CITY, FUJIAN CHINA
+86 15880910562
sales7@ca-fire.com

Hot Tags: fire protection bottom valve foot valve, China fire protection bottom valve foot valve manufacturers, suppliers, factory
Send Inquiry
You Might Also Like






