CA-FIRE ZSJZ Type Water Flow Indicator Product

CA-FIRE ZSJZ Type Water Flow Indicator Product

CA-FIRE ZSJZ Type Water Flow Indicator Product Introduction For ZSJZ Series Saddle-Type Water Flow Indicator (Models: ZSJZ 50-M-1.6 to 200-M-1.6) 0. Company Introduction CA-FIRE Fire Protection Co., LTD, founded in 2012 and located in Quanzhou, China, specializes in the R&D, manufacturing,...

Description

Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of ca-fire zsjz type water flow indicator product in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.

 

CA-FIRE ZSJZ Type Water Flow Indicator Product Introduction

For ZSJZ Series Saddle-Type Water Flow Indicator (Models: ZSJZ 50-M-1.6 to 200-M-1.6)

0. Company Introduction

CA-FIRE Fire Protection Co., LTD, founded in 2012 and located in Quanzhou, China, specializes in the R&D, manufacturing, and supply of high-quality firefighting equipment. Our product portfolio covers FM-certified fire sprinklers, alarm valves, dry/wet fire hydrants, foam systems, CCC/CE-certified nozzles, CCCF-certified lined fire hoses, and water flow indicators. We adhere to strict national and international standards (e.g., GB 5135.7-2018) and deliver reliable fire safety solutions for residential, commercial, industrial, and public facilities worldwide.

CA-FIRE's product range caters to diverse fire protection needs, including Fire Sprinklers & Accessories; Alarm Valves (Wet/Deluge/Explosion-Proof Types); Dry/Wet Fire Hydrants; Foam Extinguishing Systems; Fire Nozzles, Water Monitors & Hoses; Lined Fire Hoses; and Water Flow Indicators. All products undergo rigorous factory testing and third-party certification, ensuring compliance with local regulations and project acceptance requirements.

1. Product Overview & Core Advantages

1.1 Product Overview

The ZSJZ Type Water Flow Indicator is a critical alarm component for automatic sprinkler fire extinguishing systems, designed to convert water flow signals into electrical signals for real-time fire alerts. Compliant with GB 5135.7-2018 《Automatic Sprinkler Fire Extinguishing System - Part 7: Water Flow Indicator》, it features a saddle-type connection and rubber sensing component for sensitive and reliable operation. Widely used in medium and light hazard buildings-hotels, shopping malls, restaurants, entertainment venues, hospitals, office buildings, factories, and warehouses-it triggers alarms when water flow reaches 15~37.5 L/min, helping quickly locate fire-affected areas.

The indicator consists of a body, paddle, rubber sensing component, micro switch, and nameplate box. Its saddle-type design allows easy installation on existing pipelines (via pipe opening), and the rubber sensor ensures durable performance. With a rated working pressure of 1.6MPa and water test pressure of 3.2MPa, it withstands the pressure demands of sprinkler systems.

1.2 Core Advantages

Standard Compliance: Fully meets GB 5135.7-2018 national standards, ensuring qualification for domestic and international projects.

Precise Sensitivity: Triggers alarms at 15~37.5 L/min; no false alarms when flow ≤15 L/min, ensuring accurate fire detection.

Flexible Installation: Saddle-type connection supports on-site pipe opening installation; can be installed vertically (preferred) or adjusted for non-vertical setups with sensitivity verification.

Robust Pressure Bearing: Water test pressure of 3.2MPa (2× rated pressure) guarantees leak-proof performance and structural integrity.

Easy Operation & Maintenance: Factory-calibrated sensitivity (no user adjustment needed); simple half-yearly inspections ensure long-term reliability.

Wide Compatibility: Available in 7 models (DN50~DN200) to fit different pipeline sizes in sprinkler systems.

Durable Components: Rubber sensing component and corrosion-resistant body ensure stable operation in humid environments.

2. Technical Specifications

2.1 Core Performance Parameters

Specification Category Details
Model Series ZSJZ 50-M-1.6, ZSJZ 65-M-1.6, ZSJZ 80-M-1.6, ZSJZ 100-M-1.6, ZSJZ 125-M-1.6, ZSJZ 150-M-1.6, ZSJZ 200-M-1.6
Compliance Standard GB 5135.7-2018
Connection Type Saddle-type
Sensing Component Rubber
Rated Working Pressure 1.6MPa
Water Test Pressure 3.2MPa
Sensitivity Range Alarm: 15~37.5 L/min; No alarm: ≤15 L/min
Electrical Parameters DC 24V 1A; AC 220V 0.5A
Installation Orientation Vertical (preferred); Non-vertical (with sensitivity check)
Storage Temperature -10℃~40℃
Certifications CCC, GB 5135.7-2018 compliant

2.2 Pipe Opening & Connection Dimensions (mm)

Model Pipe Opening Size (Φ)
ZSJZ 50-M-1.6 42
ZSJZ 65-M-1.6 50
ZSJZ 80-M-1.6 50
ZSJZ 100-M-1.6 50
ZSJZ 125-M-1.6 50
ZSJZ 150-M-1.6 50
ZSJZ 200-M-1.6 84

3. Installation, Debugging & Maintenance Guidelines

3.1 Installation Requirements

Pipeline Preparation: Install on straight pipe segments with length ≥5× pipe diameter (front and rear) to ensure accurate flow sensing.

Direction Alignment: Ensure the arrow on the indicator matches the water flow direction; incorrect orientation causes failure to trigger.

Paddle Handling: Roll the sensing paddle into a cylindrical shape when inserting into the pipe; use the same method for disassembly to avoid damage.

Vertical Installation: Preferred vertical mounting with the pipeline; if non-vertical installation is necessary, verify sensitivity post-installation.

Wiring: Follow the wiring diagram to connect the electrical signal (compatible with DC 24V/1A and AC 220V/0.5A systems).

Saddle-Type Installation: Open the pipe according to instructions for saddle-type mounting; ensure a tight seal to prevent leakage.

3.2 Debugging & Operation

Post-Installation Check: Verify no burrs, welding slag, or debris in the pipeline (these can jam the paddle).

Sensitivity Verification: Test with water flow-confirm no alarm at ≤15 L/min and reliable alarm at 15~37.5 L/min.

Factory Calibration: Sensitivity is pre-adjusted at the factory; do not re-adjust unless necessary (follow sensitivity requirements if adjustment is needed).

3.3 Maintenance & Troubleshooting

3.3.1 Regular Maintenance

Conduct half-yearly inspections: Check paddle movement, wiring connections, and sensor integrity; clean debris from the pipeline if needed.

3.3.2 Common Faults & Solutions

Fault Cause Troubleshooting
No signal output (no action) Paddle misinstalled/stuck on pipe wall Adjust the paddle position for free movement
  Pipeline debris (burrs, welding slag) jamming the paddle Remove debris from the pipeline
  Incorrect installation direction Realign to match water flow (arrow direction)
Unreliable action Mismatched paddle specifications Replace with the correct paddle model
No reset/improper reset Misadjusted reset screw Adjust the reset screw to restore proper reset function

4. Packaging & Transportation

Packaging: Each water flow indicator is individually fixed in a carton to avoid collision; each package includes a certificate of conformity, instruction manual, and packing list. Cartons are marked with placement direction and moisture-proof labels.

Transportation: Prevent shock during transit; avoid dropping, throwing, or colliding during loading/unloading.

Storage: Store in a ventilated, dry warehouse (-10℃~40℃); avoid storing with corrosive substances.

5. Application Scenarios

Commercial Buildings: Hotels, shopping malls, restaurants, entertainment venues, and office buildings.

Public Facilities: Hospitals, schools, community centers, and railway stations.

Industrial & Logistics: Factories, warehouses, and logistics centers (medium and light hazard).

Residential Buildings: High-rise apartments, villa complexes, and residential underground garages.

Infrastructure: Subway stations, underground passages, and public parking garages.

6. Frequently Asked Questions (FAQ)

Q: What standard does this water flow indicator comply with?A: It fully complies with GB 5135.7-2018 《Automatic Sprinkler Fire Extinguishing System - Part 7: Water Flow Indicator》, meeting national fire safety requirements.

Q: Can the sensitivity be adjusted by the user?A: It is factory-calibrated, so users generally do not need to adjust it. If adjustment is necessary, follow the sensitivity range (15~37.5 L/min) for calibration.

Q: What pipeline length is required for installation?A: It must be installed on straight pipe segments with length not less than 5 times the pipe diameter (front and rear) to ensure accurate flow sensing.

Q: Is vertical installation mandatory?A: Vertical installation is preferred, but non-vertical installation is allowed-just verify the sensitivity after installation to ensure it meets requirements.

Q: What electrical systems is it compatible with?A: It supports both DC 24V 1A and AC 220V 0.5A electrical systems, adapting to different sprinkler system configurations.

7. Product Comparison (vs. Competitors)

Key Comparison Points CA-FIRE ZSJZ Type Water Flow Indicator Competitor A Competitor B
Compliance Standard GB 5135.7-2018 + CCC GB 5135.7-2018 Only No Formal Standard
Sensitivity Range 15~37.5 L/min (precise) 20~40 L/min (wide) 10~30 L/min (prone to false alarms)
Water Test Pressure 3.2MPa (2× rated) 2.4MPa (1.5× rated) 2.0MPa (1.25× rated)
Installation Flexibility Saddle-type (pipe opening + vertical/non-vertical) Flange-type (fixed installation) Saddle-type (vertical only)
Maintenance Frequency Half-yearly Quarterly Monthly
Component Durability Rubber sensor (anti-aging) Ordinary plastic sensor Rubber sensor (short service life)
After-Sales Warranty 2 Years 1 Year No Warranty

8. Contact: Dulcia

Email: sales8@ca-fire.com

Tel/WhatsApp: +86 191 6381 1547

WeChat: Dulcia8

Hot Tags: ca-fire zsjz type water flow indicator product, China ca-fire zsjz type water flow indicator product manufacturers, suppliers, factory