Fire Foam Tank Horizontal Tank Foam Fire Extinguishing Installation
Horizontal Fire Foam Tank (Foam Bladder Tank) - Q&A 1. Q: What is the CA-Fire Horizontal Fire Foam Tank? A: The CA-Fire Horizontal Fire Foam Tank (Model: PHYM Series, also referred to as a Foam Bladder Tank ) is a pressure-driven proportioning and mixing unit engineered exclusively for...
Description
Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of fire foam tank horizontal tank foam fire extinguishing installation in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.
Horizontal Fire Foam Tank (Foam Bladder Tank) - Q&A
1. Q: What is the CA-Fire Horizontal Fire Foam Tank?
A: The CA-Fire Horizontal Fire Foam Tank (Model: PHYM Series, also referred to as a Foam Bladder Tank) is a pressure-driven proportioning and mixing unit engineered exclusively for space-constrained high-risk environments. Its defining "horizontal" design-installed parallel to the ground-addresses a critical pain point: it fits in areas with vertical clearance as low as 1.2m, making it the go-to choice for spaces where vertical tanks are impractical, such as underground garages, low-rise industrial workshops, ship engine rooms, or retrofitted facilities with limited ceiling height.
Constructed from high-grade brass with a robust anti-corrosion red finish, this tank serves two core functions: storing foam extinguishing agent securely, and blending it with water at a precise, adjustable ratio (3% for light Class B fires like small oil spills, 6% for heavy-duty scenarios such as large chemical tank blazes). Operating at a steady 12.1bar (1.21MPa) working pressure, it seamlessly pairs with 4L/S–360L/S proportional mixers and integrates with fire suppression tools like PFS high-expansion foam generators, PZ medium-expansion generators, or PP foam monitors to form complete foam-based fire control systems.
Widely deployed in petrochemical plants, port loading platforms, oil depots, and commercial vehicle garages, it delivers reliable suppression for both Class A (solid combustibles like wood or fabric) and Class B (flammable liquids such as gasoline or diesel) fires-all while maximizing usable space in tight installations.
2. Q: What are the core advantages of this horizontal fire foam tank?
A: This horizontal foam tank stands out with 4 distinct strengths, each tailored to solve practical challenges in space-constrained fire safety scenarios-avoiding generic benefits and focusing on its unique value:
Space-Optimizing Horizontal Layout: Unlike vertical tanks that demand 3m+ ceiling height, its ground-parallel design thrives in low-clearance environments (even with vertical space as tight as 1.2m). This is a critical advantage for underground garages, ship engine rooms, or retrofitted factories where raising ceilings to fit vertical units is costly or impossible-no more sacrificing fire safety for usable space.
GB/T 5231 Brass for Long-Term Durability: Crafted from brass that meets strict GB/T 5231 standards, it resists two key threats in high-risk areas: chemical erosion from foam concentrates (common in petrochemical zones) and oxidation from humid or outdoor exposure. Unlike lower-grade metals that rust or leak after 3–5 years, this tank maintains structural integrity for over 12 years, cutting down on replacement frequency.
Pressure Stability for Consistent Foam Quality: Its 0.6–1.2MPa working pressure range is calibrated to match standard fire pump outputs, ensuring no pressure mismatches that disrupt foam mixing. With a pressure drop of ≤0.2MPa, it avoids energy waste while keeping the 3%/6% mixing ratio precise-critical for Class B fires, where uneven foam concentration can fail to smother flammable liquids.
Bulk Cost Savings + Tailored Customization: Beyond competitive bulk pricing ($1,200/unit for 2–999 units, $850/unit for ≥1,000 units), its customization goes beyond logos/packaging. We offer tank diameter adjustments (to fit specific facility nooks) and even inlet/outlet position tweaks (to align with existing pipeline layouts)-all with a 2,000-unit MOQ, making it easier to adapt to non-standard installations.
3. Q: What are the detailed technical specifications?
A: Below are two tables: model-specific parameters for the PHYM series and general technical parameters for quick reference:
Table 1: PHYM Series Model-Specific Parameters
| Model | Inlet Water Flow (L/S) | Aspiration Volume (L/S) | Mixed Liquid Volume (L/S) |
|---|---|---|---|
| PHY4 | 4 | 0.12–0.24 | 1–4 |
| PHY8 | 8 | 0.24–0.45 | 2–8 |
| PHY16 | 16 | 0.48–0.96 | 3–16 |
| PHY24 | 24 | 0.72–1.44 | 4–24 |
| PHY32 | 32 | 0.96–1.92 | 8–32 |
| PHY48 | 48 | 1.44–2.88 | 16–48 |
| PHY64 | 64 | 1.92–3.48 | 20–64 |
| PHY76 | 76 | 2.16–4.32 | 24–76 |
| PHY100 | 100 | 3.0–6.0 | 32–100 |
Table 2: General Technical Parameters
| Specification | Details |
|---|---|
| Product Type | Horizontal Fire Foam Tank (Foam Bladder Tank) |
| Material | Brass (body) |
| Color | Red |
| Working Pressure Range | 0.6–1.2MPa (12.1bar rated pressure) |
| Pressure Drop | ≤0.2MPa |
| Test Pressure | Strength: 1.5MPa; Density: 1.32MPa |
| Tank Volume | 0.5–13 m³ |
| Main Pipe Diameter | DN80–DN250 |
| Proportional Mixer Compatibility | 4L/S – 360L/S |
| Foam Mixing Ratio | 3% or 6% |
| Applicable Fire Types | Class A (solid combustibles), Class B (flammable liquids) |
4. FAQ
Q: Will this horizontal tank require modifying my existing fire pipelines?
A: No, in most cases. It's designed with a DN80–DN250 main pipe diameter, which matches standard fire pipeline sizes globally. If your existing pipelines have non-standard sizes, we offer custom inlet/outlet adapters (MOQ: 50 units) to eliminate the need for full pipeline 改造 (replacement)-saving time and retrofitting costs.
Q: How often does this tank need maintenance, and is it costly?
A: Maintenance is minimal and low-cost. We recommend quarterly checks: inspecting the brass body for corrosion, verifying the bladder's integrity (no leaks), and flushing the mixing chamber with clean water to prevent foam residue buildup. A full maintenance cycle takes less than 1 hour, and no specialized tools are needed-most on-site teams can handle it without hiring external technicians.
Q: Can I use third-party foam concentrate with this tank, or do I need CA-Fire's proprietary product?
A: It's fully compatible with most industry-standard foam concentrates, including AFFF, AR-AFFF, and protein foam-no need for proprietary products. Just ensure the concentrate's recommended mixing ratio (3% or 6%) aligns with the tank's adjustable settings, and we can provide a compatibility checklist for your chosen product upon request.
Q: For outdoor installations in coastal areas, will saltwater humidity damage the brass body?
A: The tank's brass body undergoes an extra passivation treatment (beyond standard anti-corrosion coating) to resist saltwater oxidation. In coastal tests, it maintained performance for 8+ years without rusting. For extreme coastal environments, we offer an optional marine-grade paint coating (MOQ: 100 units) that extends resistance to salt spray by 50%.
5. Q: Why choose CA-Fire Protection Co., Ltd. for this horizontal foam tank?
A: Founded in 2014 and based in Quanzhou, Fujian (China's fire protection industry hub), CA-Fire is an integrated enterprise specializing in high-performance fire equipment. Our strengths for this product include:
Horizontal Tank Expertise: We have 8+ years of experience designing horizontal foam systems, with a dedicated engineering team that optimizes tank structure for space efficiency and pressure stability-avoiding common issues like uneven foam mixing in poorly designed horizontal units.
Strict Quality Control: Raw materials (brass meets GB/T 5231 standards) are fully traceable, and every tank undergoes TüVRheinland-verified testing (pressure resistance, leakage, mixing ratio accuracy). We also maintain a 100% on-time delivery rate and ≤2-hour response time for inquiries.
Global Market Proven: Products are exported to Colombia, Argentina, Malaysia, and the Middle East-with a 93.8% customer satisfaction rate. We understand regional fire codes (e.g., NFPA for North America, EN for Europe) and can adjust tank parameters to meet local compliance requirements.
Comprehensive Support: From pre-sales site surveys (to confirm horizontal installation feasibility) to post-delivery installation guidance, we offer end-to-end service. We also provide a 12-month warranty covering manufacturing defects-ensuring long-term reliability.
6. Q: How to contact CA-Fire for inquiries or orders?
A: For product quotes, technical consultations, or custom layout requests, reach our team via:
Dulcia Chen
Phone: +86 191 6381 1547
Email: sales8@ca-fire.com
Official Website: www.cafire-119.com
Address: No.8, Yuanfeng Road, Meiyuan Village, Kangmei Town, Nan'an City, Quanzhou City, Fujian Province, China
Hot Tags: fire foam tank horizontal tank foam fire extinguishing installation, China fire foam tank horizontal tank foam fire extinguishing installation manufacturers, suppliers, factory, Fire Fighting Foam Bladder Tank, Firefighting Horizontal Foam Bladder Tank, Mobile Foam Unit Foam Tank Factory Supply, Foam Bladder Tank In Firefighting Equipment, Mobile Foam Tank Portable Foam Tank Supplier, Mobile Foam Unit Price For Firefighting
Send Inquiry
You Might Also Like