Home - Products - Foam System - Details
CA-FIRE BS 336 Foam Inductor Product

CA-FIRE BS 336 Foam Inductor Product

CA-FIRE BS 336 Foam Inductor Product Introduction For BS 336 Foam Inductor (Size: 65A) 0. Company Introduction CA-FIRE Fire Protection Co., LTD, founded in 2012 and located in Quanzhou, China, specializes in the research, development, and manufacturing of high-quality firefighting equipment. Our...

Description

Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of ca-fire bs 336 foam inductor product in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.

 

CA-FIRE BS 336 Foam Inductor Product Introduction

For BS 336 Foam Inductor (Size: 65A)

0. Company Introduction

CA-FIRE Fire Protection Co., LTD, founded in 2012 and located in Quanzhou, China, specializes in the research, development, and manufacturing of high-quality firefighting equipment. Our products include fire sprinklers (FM certified), hydrants, alarm valves, foam systems, and nozzles (CCC and CE certified). We are committed to providing reliable, durable, and compliant fire protection solutions for residential, commercial, and industrial buildings worldwide.CA-FIRE specializes in high-quality fire protection equipment. We provide a wide range of products to meet diverse fire safety needs, including: Fire Sprinklers; Indoor and Outdoor Fire Hydrants; Alarm Valves, Wet and Deluge Valves; Foam Systems, Foam Bladder Tanks, and Foam Generators; Fire Nozzles, Water Monitors, and Fire Hoses; Hose Reels, Couplings, and Accessories; Valves and Signal Devices. All products are manufactured with strict quality control and meet international fire protection standards. Custom sizes and solutions are available to suit specific project requirements.

1. Product Overview & Core Advantages

1.1 Product Overview

The BS 336 Foam Inductor (Size: 65A) is a key component of foam fire extinguishing systems, designed to accurately mix foam concentrate with water at a preset ratio. Compliant with BS 336 international standards, it operates by inducting foam concentrate into the water flow through pressure differentials, creating a homogeneous foam-water mixture that is then delivered to foam nozzles or sprinklers for fire suppression. It is specifically engineered to combat flammable liquid fires, relying on foam to isolate oxygen and cool the fire source, making it essential for high-risk environments handling oils, solvents, and other combustible liquids.

1.2 Core Advantages

BS 336 Standard Compliance: Fully meets BS 336 international standards, combined with CCC and CE certifications, ensuring compatibility and compliance in global markets.

Adjustable Foam Concentration: Supports foam concentrate mixing ratios of 1%-6%, adaptable to different fire scenarios and foam concentrate types (e.g., AFFF, FFFP).

Dual Material Options: Available in brass or aluminum construction, offering flexibility in cost and application-brass for enhanced corrosion resistance, aluminum for lightweight installation.

High Pressure Resistance: Features a working pressure of 16bar and testing pressure of 24bar, ensuring stable performance in high-pressure fire protection systems.

Secure Hose Connection: Equipped with ribbed or serrated hose tails for tight, leak-proof connections with fire hoses, preventing pressure loss during operation.

2. Technical Specifications

Specification Category Details
Model/Size 65A
Compliance Standard BS 336
Material Brass / Aluminum (optional)
Hose Tail Design Ribbed or serrated
Working Pressure 16 bar
Testing Pressure 24 bar
Foam Concentrate Mixing Ratio 1% - 6% (adjustable)
Application Foam fire extinguishing systems (for flammable liquid fires)
Certifications CCC, CE, BS 336 compliant

3. Installation & Maintenance Instructions

3.1 Installation Guidelines

Pre-Installation Preparation: Thoroughly clean the pipeline to remove debris, sediment, or rust-ensuring unobstructed flow and preventing clogging of the inductor's internal components.

Correct Orientation: Install the inductor in the foam system pipeline according to the fluid flow direction marked on the product body. Ensure the installation is level and secure to avoid vibration during operation.

Hose Connection: Connect fire hoses to the ribbed/serrated hose tails, ensuring a tight fit. Use hose clamps if necessary to prevent leakage under high pressure.

Ratio Adjustment: Set the foam concentrate mixing ratio (1%-6%) based on the fire risk level and foam concentrate manufacturer's recommendations. Test the mixture consistency after adjustment.

System Integration: Connect the inductor to the foam concentrate storage tank and water supply pipeline. Conduct a pressure test (up to 24bar) and functional test to verify mixing accuracy and no leakage.

3.2 Maintenance Tips

Regular Inspection: Periodically check the inductor for corrosion (especially aluminum models), loose connections, or damage to the hose tails. Inspect internal components for clogging by foam residue or debris.

Ratio Calibration: Re-calibrate the foam mixing ratio annually to ensure accuracy-drift in ratio can reduce fire suppression efficiency.

Cleaning Procedure: Disassemble the inductor (following manufacturer guidelines) and clean internal channels with clean water. Avoid using corrosive cleaners that may damage brass or aluminum surfaces.

Seal Maintenance: Check sealing gaskets for wear or aging; replace immediately if leaks are detected during pressure tests.

Storage Protection: For unused inductors, store in a dry, ventilated environment. Protect hose tails from impact to maintain their ribbed/serrated structure.

4. Packaging & Transportation

Our products are carefully packaged using export-standard wooden crates or wooden pallets to ensure safe transportation. This packaging method provides stability, prevents damage during handling, and guarantees that all items arrive at the customer's location in excellent condition.

5. Application Scenarios

Industrial Facilities: Oil refineries, chemical plants, petrochemical facilities, and flammable liquid processing workshops.

Storage & Logistics: Oil tanks, chemical storage tanks, fuel depots, and warehouses storing solvents, paints, or petroleum products.

Commercial Areas: Gas stations, automotive maintenance workshops, and marine fueling terminals.

Infrastructure: Port terminals, shipping docks, and railway yards handling flammable cargo.

Specialized Environments: Aircraft hangars, industrial paint booths, and areas with high fire risk from liquid combustion.

6. Frequently Asked Questions (FAQ)

Q: What is the applicable foam concentrate type for this inductor?A: It is compatible with most common foam concentrates, including AFFF (Aqueous Film-Forming Foam) and FFFP (Film-Forming Fluoroprotein Foam), as long as the mixing ratio (1%-6%) matches the concentrate's requirements.

Q: How do I choose between brass and aluminum materials?A: Brass is recommended for corrosive environments (e.g., coastal areas, chemical plants) due to its superior corrosion resistance. Aluminum is a lightweight, cost-effective option for general industrial or indoor applications.

Q: Can the mixing ratio be adjusted during a fire emergency?A: No. The ratio should be pre-set and calibrated before system activation. Adjustments during emergencies may cause mixing instability and reduce fire suppression effectiveness.

Q: What is the maximum system pressure this inductor can withstand?A: The working pressure is 16bar, and the testing pressure is 24bar. Do not exceed the working pressure during normal operation to avoid component damage.

Q: Is professional installation required for this foam inductor?A: Yes. We recommend installation by qualified fire protection technicians familiar with BS 336 standards to ensure correct integration, pressure resistance, and mixing accuracy.

7. Product Comparison Table (vs. Competitors)

Comparison Item Our BS 336 Foam Inductor (65A) Competitor A Competitor B
Compliance Standard BS 336+CCC+CE Only CE No key certifications
Material Options Brass/Aluminum Brass only Aluminum only
Mixing Ratio Range 1%-6% (adjustable) 3%-6% (fixed) 2%-4% (narrow range)
Working Pressure 16bar (stable performance) 12bar (lower pressure) 14bar (unstable at max pressure)
Hose Tail Design Ribbed/serrated (leak-proof) Smooth (prone to leakage) Ribbed only (limited compatibility)
Testing Pressure 24bar (high durability) 18bar (low tolerance) 20bar (prone to deformation)
Maintenance Cost (Annual) $12/unit $20/unit $18/unit (frequent calibration)
After-Sales Warranty 2 years + technical support 1 year No warranty
Compatibility Universal (fits most foam systems) Limited to specific systems Only for self-branded foam nozzles

8. Contact: Dulcia

Email: sales8@ca-fire.com

Tel/WhatsApp: +86 191 6381 1547 / +86 15985963342

WeChat: Dulcia8

Hot Tags: ca-fire bs 336 foam inductor product, China ca-fire bs 336 foam inductor product manufacturers, suppliers, factory

You Might Also Like

Shopping Bags