Home - Products - Fire Sprinklers - Details
Upright Fire Sprinkler Head
video
Upright Fire Sprinkler Head

Upright Fire Sprinkler Head

This upright fire sprinkler head is built for ceiling-mounted use, with an upward-facing deflector—perfect for high-ceiling spaces like warehouses and industrial workshops.
Typically FM-approved, it relies on a 68°C heat-sensitive glass bulb that activates swiftly as temperatures surge.
When triggered, its deflector spreads water evenly across overhead and surrounding areas, meeting fire safety codes to suppress early blazes effectively, protecting property and occupants in large, open interiors.

Description

Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of upright fire sprinkler head in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.

 

How to Verify the Legitimacy of FM Certification for This Upright Fire Sprinkler Head?

 

FM sprinkler 1
 
 

Upright fire sprinkler head

To verify this upright fire sprinkler head's FM certification legitimacy:

First, check the head for clear FM logos and a unique approval number (etched/printed on its body).

Second, access FM Global's official Approval Guide database online, inputting the number to confirm the product model, specs, and active certification status match.

Third, request the supplier's FM certification document copy, cross-checking manufacturing details against the physical item.

Finally, ensure the FM markings are professionally applied (no blurring) to avoid counterfeits. These steps confirm the certification is valid and the product meets FM's safety standards.

What FM-Specified Construction Standards Govern FM-Approved Sprinkler Head Installation?

 
Installing FM-approved sprinkler heads requires strict adherence to FM's construction standards:
 
First, only FM-certified fire technicians may perform the work to ensure precision.
 
Second, spacing and mounting height follow FM 13 guidelines-adjusted for ceiling type (e.g., 1.8–3.6m between heads for standard ceilings).
 
Third, all auxiliary parts (pipes, brackets) must be FM-listed to preserve system integrity.
 
Fourth, post-installation hydrostatic testing (1.5× working pressure) is mandatory to detect leaks.
 
Finally, installers must document all steps and retain compliance records for fire safety inspections, ensuring full alignment with FM's safety protocols.
 

What Test Items Are Included in FM Certification Standards for Upright Fire Sprinkler Heads?

 

Pressure Resistance Testing

FM subjects upright fire sprinkler heads to 25Bar hydrostatic pressure testing, a core standard to validate structural integrity. This test simulates extreme system pressure spikes in fire setups. For ceiling-mounted upright models, it ensures the brass body and thread connections (critical for overhead installation) stay leak-free and crack-resistant. Only units sustaining the pressure without defects pass-FM mandates this to prevent system failure during emergencies.

01

Temperature Response Testing

This FM test verifies the upright sprinkler's heat-sensitive glass bulb activates precisely at its rated temperature (e.g., 68°C/155°F). Testers use controlled, gradual temperature rises (per FM 13 guidelines) to mimic real fire heat. For upright designs, the test confirms the upward-positioned bulb reacts consistently-avoiding premature/delayed activation. FM requires this to ensure timely triggering for early blaze suppression in high-ceiling spaces.

 

02

Spray Performance Testing

FM evaluates the upright sprinkler's upward-facing deflector via spray performance testing. It measures coverage radius, water distribution uniformity, and flow rate (matched to the head's K-factor). For upright models (used in warehouses/high bays), FM mandates sufficient overhead/downward coverage to reach wide areas. The test ensures the deflector spreads water effectively, meeting fire codes for large, ceiling-mounted installations.
 

03

Durability & Seal Testing

FM's durability test cycles the upright sprinkler's activation mechanism repeatedly to simulate long-term use. The seal test checks for leaks under working pressure-vital for overhead-mounted upright heads (which face higher leak risks). FM requires the body-deflector seal to stay intact post-cycles, and the glass bulb to retain functionality. This ensures the sprinkler maintains reliability over its service life, aligning with FM's safety protocols.

 

04

Upright fire sprinkler head-Technical Parameter

 

Upright fire sprinkler head Specification
Upright fire sprinkler head Details
K Factor
K=5.6(K80)
Thread Size
R21/2"-1/2"NPT
Type Upright/Pendent/Sidewall
Glass Bulb Diameter
5mm/3mm
Frame Finish
Chrome Plated,Brass
Deflector Finish
Chrome Plated,Copper; pendent is SS material
Certificate
FM
SIN
NF3151/NF3251/NF3351/NF3131/NF3231/NF3331
product-800-800
product-800-800
product-800-800

 

product-800-800
product-800-800
product-800-800

  OUR FM APPROVAL CERTIFICATE:

product-1063-818
NF3151-NF3131
product-1050-811
NF3251-NF3231
product-1049-810
NF3351-NF3331

 

How To Cooperate With Us?

Our address

NO.8, YUANFENG ROAD, MEIYUAN VILLAGE, KANGMEI TOWN, NANAN CITY, QUANZHOU CITY, FUJIAN CHINA

Phone Number

+86 15960762930

E-mail

alison@ca-fire.com

product-943-596

 

Learn More

 

 

 

 

 

Hot Tags: upright fire sprinkler head, China upright fire sprinkler head manufacturers, suppliers, factory

You Might Also Like

Shopping Bags