DN25 Aluminum Fire Water Flow Switch, Threaded Design For Fire Pipes
The Aluminum Threaded Water Flow Switch (DN25) reliably monitors water flow in fire sprinkler systems, triggering alarms in real time. Its durable aluminum housing ensures corrosion resistance and long-lasting performance. With a threaded connection for easy installation, this switch is ideal for commercial, industrial, and residential fire protection systems, providing fast detection and enhanced safety.
Description
Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of dn25 aluminum fire water flow switch, threaded design for fire pipes in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.
Products Description

Aluminium Water Flow Switch – Threaded Connection
The DN25 Aluminum Alloy Threaded Fire Water Flow Switch is a core monitoring component for fire protection systems, designed to detect water flow status in DN25-diameter fire pipelines. Adopting high-strength aluminum alloy material (lightweight, corrosion-resistant) and standard threaded connection (e.g., NPT/G thread, compatible with universal fire pipes), it can quickly trigger alarms or linkage actions (e.g., starting fire pumps, activating fire alarms) when water flows (such as sprinkler activation or hydrant use), effectively preventing delayed fire response and improving system safety.
Product Details
| Attribute | Specification |
|---|---|
| Brand Name | CA-FIRE |
| Model | ZSJZ-25-1.6 |
| Material | Aluminum |
| Type | Water Flow Switch / Indicator |
| Connection Type | Threaded (DN25) |
| Nominal Diameter (DN) | 25 mm |
| Working Pressure | 1.6 MPa |
| Color | Silver/Red |
| Installation | Horizontal / Vertical |
| Warranty | 12 months |
| Application | Fire sprinkler & piping system |
| Package | Carton / Wooden box |
| Place of Origin | Quanzhou, China |
Core Material: Made of aluminum alloy, with surface anti-corrosion treatment (electrophoretic coating), resistant to moisture, rust, and weak chemical corrosion (suitable for long-term use in fire pipe environments with high humidity).
Sensing Structure: Built-in piston-type/leaf-type flow sensor (optional based on system demand), with adjustable sensitivity (minimum detectable flow rate: ≥10 L/min), avoiding false alarms caused by pipeline micro-flow and ensuring accurate response to effective water flow.
Technical Parameters: Working pressure range: 0.1~1.6 MPa; Operating temperature: -10℃~80℃; Electrical rating: AC 220V/DC 24V (compatible with mainstream fire control panels); Protection grade: IP65 (dustproof and waterproof, suitable for indoor/outdoor installations).
Applications & Working Principle
The switch is widely used in various fire protection systems and scenarios, including:
Automatic Sprinkler Systems: Monitors whether sprinkler heads are activated (e.g., in commercial buildings, shopping malls, residential areas)-when water flows, it triggers the fire alarm system and links to start the fire pump.
Fire Hydrant Systems: Detects water outflow from indoor/outdoor fire hydrants (e.g., industrial workshops, warehouses)-prevents unauthorized use of hydrants and ensures timely response to fire extinguishing operations.
Fire Pump Rooms: Links with fire pumps to confirm whether the pump is delivering water normally; if no water flow is detected after pump startup, it sends a fault signal to avoid "empty operation" damage to the pump.
Emergency Fire Pipelines: Used in special places such as data centers, chemical plants, and power stations-monitors the water flow status of emergency fire pipelines and coordinates with fire-fighting linkage systems (e.g., cutting off power to non-essential equipment).
Working Principle
The switch operates based on the "mechanical trigger + electrical signal transmission" mechanism, with the following steps:
Standby State: When there is no water flow in the fire pipeline, the built-in sensor (piston/leaf) remains in the initial position under the action of a return spring, and the internal electrical contact is disconnected-no signal is output.
Flow Detection: When a fire occurs (or the pipeline is activated), water flows in the pipeline, and the water pressure/flow pushes the sensor to overcome the spring force and move.
Signal Trigger: The moving sensor drives the mechanical linkage component, closing the internal electrical contact (or activating the electronic sensor), generating a "water flow detected" signal (normally open/normally closed optional).
Linkage Response: The signal is transmitted to the fire control room (or alarm controller) via wires, triggering audible and visual alarms, starting fire pumps, or linking other fire-fighting equipment (e.g., smoke exhaust fans).
System Reset: After the fire is extinguished and the pipeline water flow stops, the sensor resets under the action of the return spring, the electrical contact disconnects, and the system returns to the standby state.


How to Choosea Water Flow Switch
Lightweight & Corrosion-Resistant: Aluminum alloy material is 40% lighter than cast iron switches, easy to install; anti-corrosion coating ensures a service life of ≥8 years (suitable for humid or outdoor environments).
Quick Installation & Strong Compatibility: Threaded connection eliminates welding, and it is compatible with DN25 fire pipelines of various standards (NPT/G thread); color-coded wiring terminals reduce installation errors.
High Sensitivity & Low False Alarm Rate: Adjustable flow sensitivity (10~50 L/min) adapts to different system requirements; the built-in buffer structure avoids false triggers caused by pipeline water pressure fluctuations.
Wide Environmental Adaptability: Withstands a temperature range of -10℃~80℃ and a pressure range of 0.1~1.6 MPa, suitable for cold regions, high-temperature workshops, and high-rise building pipelines.

FAQ
Q1: What thread specifications does the DN25 switch support?
A1: It supports NPT (U.S. standard) and G (metric) threads by default; custom threads (e.g., BSPT) can be provided for special needs. Confirm the pipeline thread standard before purchasing.
Q2: Why does the switch trigger a false alarm?
A2: Common reasons include: 1. Pipeline water pressure fluctuates sharply (e.g., pump startup/shutdown); 2. Debris (e.g., rust, welding slag) blocks the sensor, causing it to be stuck; 3. The sensitivity is set too low. Solution: Check the pipeline pressure stability, clean the sensor, and adjust the sensitivity according to the manual.
Q3: Can the switch be installed horizontally and vertically?
A3: Yes, but it must be installed in a straight section of the pipeline (at least 5 times the pipe diameter before the switch and 3 times after) to ensure stable water flow; avoid installing at elbows or tees (easy to cause turbulent flow affecting detection).
Q4: What should I do if the switch does not output a signal after water flows?
A4: Step 1: Check if the wiring is loose or reversed (refer to the wiring diagram); Step 2: Disassemble the switch to check if the sensor is stuck (clean with clean water); Step 3: Test the electrical contact with a multimeter (replace the internal contact if it is faulty).
Q5: Is the switch suitable for high-temperature fire pipelines (e.g., near boilers)?
A5: The standard model tolerates up to 80℃; for high-temperature scenarios (80~120℃), please select the high-temperature version (with high-temperature resistant seals and aluminum alloy material), which meets the EN 54-22 high-temperature test requirements.