Home - Products - Fire Sprinklers - Details
QLD6.0/8III-B Multi-Function Fire Nozzle

QLD6.0/8III-B Multi-Function Fire Nozzle

This QLD6.0/8III-B multi-functional fire hose, although lacking the intelligence of automatic fire suppression, is the most reliable "core of tactics" in the hands of firefighters. Its flow regulation, mode switching, and ergonomic design enable it to adapt to various complex scenarios ranging from indoor initial fires to chemical explosions. Only by understanding its professional value and strictly following the operational and maintenance norms can this "small tool" truly safeguard the safety bottom line of life and property.

Description

Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of qld6.0/8iii-b multi-function fire nozzle in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.

 

 

Products Description

 

product-800-800
 
 

CA-FIRE QLD6.0/8III-B Multi-Function Fire Nozzle

1. Precise Interpretation of Model and Key Parameters

Model Significance: "QLD" is the abbreviation of "Qiang (Nozzle)", "Liu (Flow)", and "Duo (Multi-function)" in Chinese; "6.0" indicates a rated working pressure of 0.6 MPa (6 Bar); "8" refers to a rated flow rate of 8 L/s (approx. 480 LPM), which is highly consistent with the 475 LPM specified in the export technical data sheet.

Material Advantages: The main body is made of aluminum alloy with anodized anti-corrosion treatment, weighing only 1.8 kg-40% lighter than traditional copper nozzles. This significantly reduces physical fatigue for firefighters during prolonged operations. The anodized layer not only resists corrosion but also maintains structural stability under high temperatures in fire scenes, preventing operational failures caused by thermal deformation.

2. Precision Control Based on Fluid Dynamics

Flow Rate Adjustment: Rotating the front adjustment ring enables stepless flow regulation from 115 to 475 LPM. This design adheres to the fluid dynamics formula Q=K×P​: at the rated pressure of 6 Bar, the maximum flow rate reaches 100% of the designed value, meeting the water supply requirements of different fire points.

Jet Mode Switching: The 150° rotatable nozzle head allows smooth transition from direct jet to 120° wide-angle spray. In direct jet mode, water is compressed into a high-density column with a maximum effective range of over 33 meters, ideal for long-distance suppression of Class A (solid fuel) fires. In spray mode, water is atomized into droplets of 100–1000 μm in diameter-its surface area is 3–5 times that of a direct jet, significantly improving cooling efficiency and making it a core tool for explosion-proof cooling in Class B (liquid) and Class C (gas) fire scenarios.

3. Ergonomic Optimization for Field Operations

Full-Time Swivel Joint: The 360° freely rotatable swivel joint at the tail effectively prevents hose twisting, avoiding flow attenuation or operational control failure caused by kinked hoses.

Horseshoe Valve Handle: With an operating torque of 7.7 N·m, it ensures sealing performance when the valve is closed while allowing firefighters to easily control the water flow with one hand, enabling "one-click water shutoff" in emergencies.

Non-Slip Grip: The ergonomic non-slip grip provides stable holding power even when firefighters wear gloves or work in wet conditions, reducing the impact of recoil on operation accuracy.

Multi-Scenario Tactical Applications

1. Class A Fires (Solid Combustibles): Precision Suppression and Cooling

For fires involving solids such as wood, fabrics, and plastics, the direct jet mode of this nozzle can strike fire points from a distance to quickly lower the fire scene temperature; the spray mode, on the other hand, enables comprehensive cooling of the combustion area to prevent re-ignition. For example, during a furniture mall fire, firefighters first used the direct jet mode to penetrate thick smoke and suppress the fire deep in the shelves, then switched to the spray mode to cool the entire area, effectively avoiding fire re-ignition.

Fire Safety Knowledge Extension: The core of suppressing Class A fires is "cooling". Water has a high specific heat capacity of 4.2 kJ/(kg·℃)-1 kg of water can absorb 336 kJ of heat when heated from 20℃ to 100℃, making it the most cost-effective cooling medium.

2. Class B Fires (Liquids/Molten Solids): Explosion Prevention and Isolation

Direct jetting on fires involving flammable liquids such as gasoline, diesel, and paint can cause liquid splashing and fire spread. The spray mode of this nozzle forms a water curtain with a thickness of ≥0.5 meters, which can both cool the liquid surface to prevent temperature rise and isolate oxygen to inhibit combustion. During a gas station fire, firefighters used the spray mode to form a water curtain, successfully preventing the fire from spreading to the oil tank area.

Fire Safety Knowledge Extension: Suppressing Class B fires follows the principle of "control first, extinguish later". The role of water spray is "fire control" rather than direct extinguishing. After the liquid surface temperature drops below the ignition point, foam extinguishing agents should be used for complete suppression.

3. Personnel Evacuation and Protection: Water Curtain Shielding

In high-rise buildings or crowded places, the spray mode can form a "water wall" that effectively blocks thermal radiation and thick smoke, creating a safe passage for personnel evacuation. During an office building fire, firefighters used the spray mode to form a water curtain in the stairwell, successfully covering the evacuation of 12 trapped people from the 15th floor to a safe area.

Fire Safety Knowledge Extension: Thermal radiation is one of the main causes of casualties in high-rise building fires. A water spray curtain can reflect more than 90% of thermal radiation, reducing the ambient temperature from over 600℃ to a range tolerable to the human body.

product-800-800

Safety Guidelines for Installation, Operation and Maintenance

 

Operational Specifications

Pressure Control: The working pressure must be stabilized between 2–16 Bar (0.2–1.6 MPa), with a rated pressure of 6 Bar. Low pressure will cause range attenuation, while excessive pressure may damage the nozzle or generate excessive recoil, endangering operational safety.

Mode Switching: When switching jet modes, rotate the adjustment ring slowly to avoid water hammer effects caused by sudden water flow changes, which may damage the pipe network or hoses.

Live Electrical Fire Prohibition: When suppressing fires involving live electrical equipment, the direct jet mode is strictly prohibited. The spray mode must be used, and a safe distance of at least 5 meters must be maintained to prevent electric shock.

Maintenance Protocols

Post-Use Cleaning: Rinse the nozzle body with clean water immediately after use, and remove sediment and debris from the nozzle to prevent clogging.

Monthly Inspections: Check the flexibility of the valve, the condition of the sealing ring (for aging), and the smooth operation of the swivel joint.

Annual Pressure Testing: Conduct a hydrostatic test at 1.5 times the rated pressure (9 Bar) to verify the sealing performance and structural strength of the nozzle.

Storage Requirements: Store in a dry and well-ventilated place, away from direct sunlight, to prevent aging of rubber sealing rings.

Common Misconceptions

Myth 1: "The higher the flow rate, the better" - Blindly pursuing high flow rates will cause a sharp drop in pipe network pressure, affecting the normal operation of other fire-fighting facilities. The flow rate should be adjusted reasonably according to the size of the fire point.

Myth 2: "Spray mode is universal" - Although the spray mode is effective for cooling, it has a shorter range and insufficient suppression capacity for fire points in open areas. It must be used in conjunction with the direct jet mode.

Myth 3: "Maintenance is unnecessary" - Nozzle clogging can reduce the flow rate by more than 30%, and aging sealing rings can cause water leakage. These minor faults may lead to fire suppression failure at critical moments.

FAQ

Q1: What is the maximum pressure?
Up to 2.5 MPa for effective high-pressure spraying.

Q2: Can I adjust the spray pattern?
Yes, nozzle allows switching between stream, jet, or mist modes.

Q3: What hoses are compatible?
Standard 1/2" or 3/4" threaded hoses, with quick-connect options available.

Q4: Is it suitable for agriculture?
Yes, ideal for crop irrigation and dust suppression.

Q5: How to maintain the water gun?
Rinse after use, check for wear, and replace seals as needed.

 

 

How To Cooperate With Us?
 