Home - Products - Fire Sprinklers - Details
NONFIR Fire Sprinkler Product FM Approved
video
NONFIR Fire Sprinkler Product FM Approved

NONFIR Fire Sprinkler Product FM Approved

NONFIR Fire Sprinkler Product Introduction For NONFIR Fire Sprinkler (Models: NF3151, NF3251, NF3351) 0. Company Introduction CA-FIRE Fire Protection Co., LTD, founded in 2012 and located in Quanzhou, China, specializes in the research, development, and manufacturing of high-quality firefighting...

Description

Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of nonfir fire sprinkler product fm approved in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.

 

NONFIR Fire Sprinkler Product Introduction

For NONFIR Fire Sprinkler (Models: NF3151, NF3251, NF3351)

0. Company Introduction

CA-FIRE Fire Protection Co., LTD, founded in 2012 and located in Quanzhou, China, specializes in the research, development, and manufacturing of high-quality firefighting equipment. Our products include fire sprinklers (FM certified), hydrants, alarm valves, foam systems, and nozzles (CCC and CE certified). We are committed to providing reliable, durable, and compliant fire protection solutions for residential, commercial, and industrial buildings worldwide.CA-FIRE specializes in high-quality fire protection equipment. We provide a wide range of products to meet diverse fire safety needs, including: Fire Sprinklers; Indoor and Outdoor Fire Hydrants; Alarm Valves, Wet and Deluge Valves; Foam Systems, Foam Bladder Tanks, and Foam Generators; Fire Nozzles, Water Monitors, and Fire Hoses; Hose Reels, Couplings, and Accessories; Valves and Signal Devices. All products are manufactured with strict quality control and meet international fire protection standards. Custom sizes and solutions are available to suit specific project requirements.

1. Product Overview & Core Advantages

1.1 Product Overview

The NONFIR Fire Sprinkler series (Models: NF3151 Upright, NF3251 Pendent, NF3351 Sidewall) is a standard-response fire suppression device engineered with a K-factor of 5.6 (80.6) for reliable initial fire control. Designed to comply with global fire safety standards, this sprinkler provides consistent water distribution and rapid heat response, making it a critical component for life and property protection in various building types. It features an intact glass ball with visible bubbles (approximately 1.6mm in diameter) that ensures precise activation at specified temperatures.

1.2 Core Advantages

Multi-International Certification: Fire sprinklers hold FM certification, with other product lines certified by CCC and CE, fully complying with NFPA, FM, EN, Vds, LPCB, and local regulations for global market access.

Superior Performance: Standard response design ensures quick activation; factory test pressure of 500psi (34.5bar) and minimum working pressure of 7psi (0.5bar) guarantee stable operation in emergency scenarios.

Durable Material Selection: Upright and sidewall deflectors are made of copper, while pendent deflectors use S304 stainless steel, ensuring corrosion resistance and long service life.

Flexible Installation Options: Available in upright, pendent, and sidewall types, compatible with 1/2" NPT or ISO7-1 standard pipe threads, adapting to diverse piping layouts.

2. Technical Specifications

Specification Category Details
Model Numbers NF3151 (Upright), NF3251 (Pendent), NF3351 (Sidewall)
Coverage Type Standard Coverage
K-Factor K5.6 (80.6)
Connection Thread 1/2" NPT or ISO7-1
Installation Torque (DN15) 10-20N·m
Factory Test Pressure 500psi (34.5bar)
Minimum Working Pressure 7psi (0.5bar)
Storage Temperature Range -15℃ to 40℃
Deflector Material Upright/Sidewall: Copper; Pendent: S304 Stainless Steel
Dimensions Tolerance ±0.3mm
Certifications FM, CCC, CE

3. Installation & Maintenance Instructions

3.1 Installation Guidelines

Pre-Installation Preparation: Installation personnel must master sprinkler principles, relevant construction specifications, and manufacturer instructions. Ensure the spray pipe network is fully washed and cleaned before installation.

Timing of Installation: Install the sprinkler after completion of other construction and decoration projects. If modifications or mixed construction are unavoidable, cover the sprinkler with effective protection.

Thread Preparation: When wrapping Teflon film or applying non-curable pipe thread adhesive, avoid the first thread to prevent blockage of the sprinkler orifice.

Secure Installation: Hand-place the sprinkler into the tee joint, then use a 22mm open-end wrench or special wrench to tighten via the base opening. Ensure firm installation and accurate orientation; do not adjust by overtightening.

Protection Clip Handling: Remove the red plastic protection clip (by hand from the side socket, no metal tools allowed) only after all construction is completed and before the sealing test. Reinstall the clip if additional construction is needed post-test.

Post-Installation Check: After tightening, inspect the glass ball for integrity (no leakage or missing working fluid) and confirm the sprinkler arm and deflector are undamaged.

3.2 Maintenance Tips

Regular Inspection: Periodically check for hanging foreign objects, spider webs, or coating damage; clean surface dust with a feather duster (avoid hot water, corrosive cleaners, or ammonia water).

Abnormal Replacement: Replace sprinklers with damaged glass balls (loss of working fluid), dropped units, or disassembled units immediately.

System Maintenance Protocol: Obtain relevant management department approval before closing fire control system valves for maintenance; drain residual water in pipes to avoid water damage during sprinkler disassembly.

Professional Maintenance: Recommended to be performed by qualified inspection institutions or trained specialists to ensure compliance with standards.

4. Packaging & Transportation

Our products are carefully packaged using export-standard wooden crates or wooden pallets to ensure safe transportation. This packaging method provides stability, prevents damage during handling, and guarantees that all items arrive at the customer's location in excellent condition.

5. Application Scenarios

Residential Buildings: Apartments, villas, residential complexes

Commercial Buildings: Shopping malls, office buildings, hotels, restaurants, hospitals, schools

Industrial Facilities: Factories, workshops, warehouses (excluding high-hazard environments beyond standard coverage)

Public Infrastructure: Railway stations, airports, subway stations, community centers

Other Spaces: Parking garages, underground passages, small-to-medium-sized public assembly areas

6. Frequently Asked Questions (FAQ)

Q: Does this sprinkler comply with NFPA and FM standards?A: Yes, the NONFIR Fire Sprinkler is FM certified and fully complies with NFPA, FM, EN, Vds, LPCB, and CCC standards, meeting global fire safety regulatory requirements. We can provide certification reports for customs clearance and project acceptance.

Q: What is the difference between the three models (NF3151/NF3251/NF3351)?A: They differ in installation type: NF3151 is upright, NF3251 is pendent, and NF3351 is sidewall. All share the same K-factor (K5.6) and performance parameters, suitable for different piping and space layouts.

Q: How often should the sprinkler be inspected and maintained?A: Daily visual inspections are recommended to check for obstacles or damage; professional maintenance and inspection by qualified personnel are suggested annually to ensure optimal performance.

Q: Can the sprinkler be reused after being dropped?A: No. Dropped sprinklers must be scrapped immediately, as internal damage (invisible to the naked eye) may affect activation reliability in fires.

Q: What is the temperature range for storage and operation?A: The sprinkler should be stored in a dry environment between -15℃ and 40℃, avoiding direct sunlight or local high-temperature areas. It operates within standard fire suppression temperature ranges as specified by global standards.

7. Product Comparison Table (vs. Competitors)

Comparison Item Our NONFIR Fire Sprinkler    
International Certification FM+CE+CCC    
Material Quality Copper/S304 deflector    
Factory Test Pressure 500psi (34.5bar)    
Installation Flexibility 3 types (upright/pendent/sidewall)    
Maintenance Cost (Annual) $15/unit    
After-Sales Warranty 2 years + technical support    
Compatibility 1/2" NPT/ISO7-1 standard threads (universal)    

8. Contact: Dulcia

Email: sales8@ca-fire.com

Tel/WhatsApp: +86 191 6381 1547

WeChat: Dulcia8

Hot Tags: nonfir fire sprinkler product fm approved, China nonfir fire sprinkler product fm approved manufacturers, suppliers, factory

You Might Also Like

Shopping Bags