Dry Pendent Fire Sprinkler For Dry And Pre-Action Fire Protection Systems
The dry-type pendent fire sprinkler is designed for freezing environments and dry or pre-action systems. Featuring an imported glass bulb or fusible alloy, it prevents water accumulation and freezing damage. Multiple K-factors and temperature ratings provide flexible design options and reliable fire protection performance.
Description
Products Description

CA-FIRE Dry Pendent Fire Sprinkler
The dry-type pendent fire sprinkler is a high-standard, high-quality fire protection product featuring an imported German glass bulb and a metal sealing spring assembly, ensuring precise temperature response and long-term sealing reliability.
In dry pipe and pre-action sprinkler systems, conventional pendent sprinklers may suffer irreversible damage when residual water or condensation inside the sprinkler body freezes and expands at temperatures below 0°C. This can lead to cracking, leakage, and system failure.
The dry-type pendent sprinkler is specifically designed to eliminate this risk. Its sealing assembly is positioned at the top of the installation pipe, leaving the entire connection section free of water. This structural design effectively prevents freezing caused by trapped water or condensation, even in low-temperature environments.
This sprinkler is ideal for installations where sprinklers or connecting pipes are exposed to freezing conditions, or where sprinkler systems require seasonal drainage. Typical applications include cold storage facilities, unheated warehouses, parking garages, and outdoor or semi-outdoor structures.
| Item | Specification |
|---|---|
| Flow Coefficient (K-Factor) | K = 80 / K = 115 / K = 161 / K = 202 |
| Nominal Operating Temperature | 57°C / 68°C / 79°C / 93°C / 141°C |
| Maximum Ambient Temperature | 27°C / 38°C / 49°C / 63°C / 111°C |
| Glass Bulb Color | Orange / Red / Yellow / Green / Blue |
| Connection Thread | Rp 1 (K = 80 / K = 115)Rp 1 1/4 (K = 161 / K = 202) |
| Sensing Element | Glass Bulb (5 mm / 3 mm)Fusible Alloy (K = 202) |
| Response Time Index (RTI) | 5 mm Bulb: 50–80 (m·s)0.53 mm Bulb & Fusible Alloy: ≤ 50 (m·s)0.5 |
| Installation Type | Pendent |
Application & Advantages
The dry-type pendent fire sprinkler is a high-performance solution engineered for precision and durability in challenging environments.
Key Advantages
Superior Sealing & Precision: Features a high-quality imported German glass bulb and a metal sealing spring assembly to ensure accurate thermal response and long-term leak prevention.
Anti-Freeze Protection: Specifically designed to prevent the cracking and leakage common in conventional sprinklers when residual water or condensation freezes and expands.
Innovative Dry Design: The sealing assembly is strategically placed at the top of the pipe, keeping the entire connection section water-free to eliminate the risk of ice damage.
High Manufacturing Standards: Built to high-quality standards to ensure stable performance under varied conditions.
Ideal Applications
Cold Storage & Warehousing: Essential for cold storage facilities and unheated warehouses where temperatures frequently drop below freezing.
Exposed Structures: Ideal for parking garages, outdoor structures, or semi-outdoor locations.
Dry/Pre-action Systems: Designed specifically for dry pipe and pre-action systems that require seasonal drainage or are exposed to freezing conditions.


Installation Requirements
The dry-type pendent fire sprinkler is a high-standard, high-quality fire protection product designed for environments where freezing is a concern.
Key Advantages
High-Quality Components: Features an imported German glass bulb and a metal sealing spring assembly to ensure precise temperature response and long-term sealing reliability.
Anti-Freeze Design: Specifically engineered to prevent irreversible damage, such as cracking or system failure, caused by water freezing and expanding inside the sprinkler body.
Innovative Structure: The sealing assembly is positioned at the top of the installation pipe, keeping the connection section free of water and preventing ice formation from trapped condensation.
Mechanical Protection: The design reduces the risk of accidental impact or damage in crowded environments or locations with frequent goods handling.
Typical Applications
Cold Environments: Ideal for installations where sprinklers or connecting pipes are exposed to temperatures below 0°C.
Specific Facilities: Widely used in cold storage facilities, unheated warehouses, and parking garages.
Outdoor Use: Suitable for outdoor or semi-outdoor structures and systems requiring seasonal drainage.
OUR CERTIFICATE: