Copper Glass Bulb Deluge Sprinkler Head For Industrial & Commercial Fire Protection
video
Copper Glass Bulb Deluge Sprinkler Head For Industrial & Commercial Fire Protection

Copper Glass Bulb Deluge Sprinkler Head For Industrial & Commercial Fire Protection

The copper glass bulb deluge sprinkler head is designed for rapid fire suppression in large-span industrial buildings, warehouses, commercial complexes, and outdoor storage areas. Its heat-sensitive glass bulb activates instantly at the specified temperature, releasing water uniformly to control and suppress fires. Built with durable copper alloy, it ensures long-term reliability even in harsh environments. Ideal for high-risk areas, this deluge sprinkler provides fast response, wide coverage, and enhanced safety for personnel and assets.

Description

Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of copper glass bulb deluge sprinkler head for industrial & commercial fire protection in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.

 

 

Products Description

 

Deluge Sprinkler Head
 
 

Copper Glass Bulb Deluge Sprinkler Head

The copper glass bulb deluge sprinkler head is an essential component of automatic fire suppression systems, specifically designed for large-span industrial facilities, warehouses, logistics centers, commercial complexes, and outdoor storage yards. It features a heat-sensitive glass bulb that responds quickly to rising temperatures, automatically activating when the ambient temperature reaches the designated nominal point. Once activated, water is released immediately and dispersed evenly through the specially designed deflector plate, covering a wide area and ensuring that the fire is controlled rapidly with minimal damage. Constructed from high-strength copper alloy, this sprinkler offers excellent durability, corrosion resistance, and long-term stability, making it suitable for harsh or demanding environments. Its precise thermal response ensures that water is deployed only when necessary, reducing unnecessary water usage while maximizing fire suppression efficiency. The sprinkler's design allows for multiple installation types, including pendant, upright, and sidewall orientations, providing flexibility for various building layouts and fire protection needs. With both 3mm rapid-response and 5mm standard-response glass bulbs, the sprinkler adapts to different operational requirements, ensuring reliable performance in any large or high-risk setting.

Technical Parameters

Parameter Specification
Nominal Diameter DN15 (R1/2"), DN20 (R3/4"), DN25 (R1")
K-Factor K=80 (DN15), K=115 (DN20), K=202/242/363 (high flow models)
Rated Working Pressure 1.2 MPa
Factory Test Pressure 3.0–3.45 MPa
Response Time Index (RTI) 28 ± 8 (m·s)
Installation Type Pendant, upright, sidewall horizontal

Nominal Activation Temperature & Bulb Color

Activation Temperature Max Ambient Temperature Glass Bulb Color
57℃ 27℃ Orange
68℃ 38℃ Red
79℃ 49℃ Yellow
93℃ 63℃ Green
141℃ – Blue

 

Deluge Sprinkler Head

Deluge Sprinkler Head

 

Fire Dynamics & Deluge System Strategy

Deluge sprinkler systems are specifically designed to address high-intensity fires that spread rapidly in large or high-risk areas. Unlike standard sprinklers that activate individually, deluge systems flood entire zones simultaneously, providing immediate suppression and preventing the fire from reaching critical temperatures.

Rapid Fire Suppression in High-Intensity Fires

Fires involving flammable liquids, chemicals, or high-density storage can escalate within seconds. Deluge sprinklers release a large volume of water instantly, lowering ambient temperature and suppressing flames before flashover occurs.

The fast response of heat-sensitive glass bulbs ensures the system activates at the precise moment the environment reaches a dangerous thermal threshold, reducing fire growth exponentially.

Thermal Layer Interaction

In high-ceiling warehouses or atriums, heat rises and forms distinct thermal layers. Deluge sprinklers are positioned strategically to intercept these layers, dispersing water effectively across upper zones to cool surfaces and interrupt vertical fire spread.

The design of the deflector plate and droplet size is optimized to penetrate these thermal layers, ensuring that water reaches hotspots that are often missed by standard sprinklers.

Strategic Zone Flooding

Deluge systems are often divided into zones, allowing targeted flooding of high-risk areas while minimizing water usage in lower-risk sections.

By analyzing fire dynamics, engineers can determine optimal spacing, K-factor, and flow rates to ensure maximum suppression efficiency while maintaining system reliability.

Integration with Fire Modeling

Modern fire protection strategy uses computational fluid dynamics (CFD) and 3D fire modeling to simulate how flames, smoke, and heat propagate. Deluge sprinkler placement is informed by these simulations to ensure rapid activation and full coverage of vulnerable areas.

Such data-driven design reduces the likelihood of fire spreading to critical assets and helps meet strict industrial fire safety requirements.

Deluge Sprinkler Head

Deluge Sprinkler Head

Long-Term Operational Considerations

Ensuring the long-term reliability of deluge sprinkler systems is critical for continuous fire protection in industrial, commercial, and high-risk facilities. Proper material selection, maintenance, and monitoring strategies significantly improve system performance over time.

System Reliability Under Stress

Deluge sprinklers must withstand fluctuating water pressures, occasional water hammer, and variations in flow without compromising performance.

Copper alloy construction and precise manufacturing tolerances ensure the sprinkler remains functional even under extreme conditions.

Robust design reduces the likelihood of accidental activation or malfunction during critical fire events.

Corrosion and Environmental Resistance

Industrial plants, chemical storage facilities, and outdoor installations expose sprinklers to humidity, chemical vapors, and temperature fluctuations.

High-quality copper alloy bodies, along with optional protective coatings, prevent corrosion, ensuring consistent performance over years of operation.

Regular environmental assessments help determine whether additional protective measures are needed.

Maintenance and Inspection Protocols

Scheduled inspections of glass bulbs, seals, deflectors, and strainers prevent unexpected failures and ensure readiness.

Annual or semi-annual water flow and pressure testing confirm system operability and detect potential issues before emergencies occur.

Maintenance routines also include verifying sprinkler orientation, clearance, and unobstructed coverage.

Operational Efficiency

Risk-based system design combined with proper maintenance ensures that deluge sprinklers only activate when necessary, minimizing water waste.

Reliable operation over time reduces downtime, protects assets, and maintains compliance with industrial safety regulations.

Documentation and Record Keeping

Keeping detailed maintenance logs, inspection reports, and component replacement records ensures traceability and supports safety audits.

Proper documentation aids in regulatory compliance and helps identify patterns that could indicate emerging issues.

Deluge Sprinkler Head
Deluge Sprinkler Head
Deluge Sprinkler Head
How To Cooperate With Us?
 

Our address

NO.8, YUANFENG ROAD, MEIYUAN VILLAGE, KANGMEI TOWN, NANAN CITY, QUANZHOU CITY, FUJIAN CHINA

 
WhatsApp

+86 18160950625

 

E-mail

miki@ca-fire.com

product-943-596

 

Hot Tags: copper glass bulb deluge sprinkler head for industrial & commercial fire protection, China copper glass bulb deluge sprinkler head for industrial & commercial fire protection manufacturers, suppliers, factory

You Might Also Like

Shopping Bags