Fire Protection Concealed Fire Sprinklers
The Fire Protection Concealed Fire Sprinklers is a high-performance Concealed Fire Sprinkler (often designated as a Concealed Fire Sprinkler Head, or simply Concealed Sprinkler) — a core component of modern Concealed Fire Sprinkler Systems, engineered to balance unobtrusive aesthetics with reliable fire suppression for upscale interior environments. This device is fully recessed within suspended ceilings, with only a flush-mount decorative cover visible, making it ideal for spaces where exposed fire safety components would disrupt decor coherence or risk accidental damage.
Description
Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of fire protection concealed fire sprinklers in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.
Products Description

Fire Protection Concealed Fire Sprinklers
The Fire Protection Concealed Fire Sprinklers is a high-performance Concealed Fire Sprinkler (often designated as a Concealed Fire Sprinkler Head, or simply Concealed Sprinkler) - a core component of modern Concealed Fire Sprinkler Systems, engineered to balance unobtrusive aesthetics with reliable fire suppression for upscale interior environments. This device is fully recessed within suspended ceilings, with only a flush-mount decorative cover visible, making it ideal for spaces where exposed fire safety components would disrupt decor coherence or risk accidental damage.
| Item | Specification |
|---|---|
| Flow Coefficient (K-Factor) | K = 80 / K = 115 |
| Nominal Operating Temperature | 57°C / 68°C / 79°C / 93°C / 141°C |
| Maximum Ambient Temperature | 27°C / 38°C / 49°C / 63°C / 111°C |
| Glass Bulb Color | Orange / Red / Yellow / Green / Blue |
| Connection Thread | Rp 1/2 (K=80) ; Rp 3/4 (K=115) |
| Sensing Element | Glass Bulb (5mm / 3mm) |
| Minimum Ambient Temperature | 4°C |
| Response Time Index (RTI) | 5mm Bulb: 50–80 (m·s)0.53mm Bulb: ≤ 50 (m·s)0.5 |
| Installation Type | Pendent (Concealed Type) |
Structural & Material Advantages
How we started

A
Concealed Sprinkler Aesthetic Integration for Concealed Fire Sprinkler Systems
The flame-retardant decorative cover (customizable in white, beige, or metallic finishes) sits flush with ceiling surfaces, matching gypsum, aluminum, or wood-grain suspended ceilings typical of Concealed Fire Sprinkler System installations. This design eliminates visual conflict with high-end interiors while maintaining full fire suppression functionality.

B
Dual-Stage Activation (Concealed Fire Sprinkler Head Core Function)
As a Concealed Fire Sprinkler Head, it operates in two synchronized steps for reliable response within a Concealed Fire Sprinkler System:
The outer fusible alloy housing (matched to the bulb's rated temperature) melts, detaching the decorative cover to expose the sprinkler core.
The 9mm heat-sensitive glass bulb (filled with temperature-responsive fluid) shatters as fluid expands, triggering 360° (DN15) or 270° (DN20) water distribution via the 304 stainless steel deflector.

C
Durability for Long-Term Concealed Fire Sprinkler System Standby
Chrome-Plated Brass Base: Resists corrosion in humid Concealed Fire Sprinkler System ceiling environments, with a 12+ year service life.
EPDM Sealing Ring: Maintains zero leakage under 3.0MPa test pressure, ensuring Concealed Sprinkler reliability during long-term standby
Installation & Maintenance for Concealed Fire Sprinkler System Integration
1 Concealed Sprinkler Installation in Concealed Fire Sprinkler Systems
Ceiling Compatibility: For 15-30mm thick suspended ceilings (standard in Concealed Fire Sprinkler Systems).
Tool Restriction: Use only the manufacturer-provided dedicated wrench to install this Concealed Fire Sprinkler Head - avoid pipe wrenches/socket extensions (excessive torque deforms the brass base and causes leaks).
System Pressure Test: After installation in the Concealed Fire Sprinkler System, conduct a 1.2MPa 15-minute pressure test to confirm no base-thread leakage.
Aesthetic Alignment: Ensure the Concealed Sprinkler's decorative cover is flush with the ceiling; adjust the mounting base depth for misalignment.
2 Concealed Fire Sprinkler Head Maintenance
Monthly Concealed Sprinkler Check: Inspect the decorative cover for looseness/damage; ensure no debris blocks the Concealed Fire Sprinkler Head's activation path (critical for Concealed Fire Sprinkler System reliability).
Quarterly Concealed Fire Sprinkler System Verification: Confirm the fusible alloy housing is securely attached (do not remove the cover unless testing the Concealed Sprinkler).
Storage: Uninstalled Concealed Fire Sprinkler Heads must be stored in dry conditions (-15℃~40℃) for Concealed Fire Sprinkler System deployment.
Replacement: Replace any Concealed Sprinkler with cracked bulbs, deformed bases, or discolored housings - disassembly/repair is prohibited.
OUR CERTIFICATE


Our address
NO.8, YUANFENG ROAD, MEIYUAN VILLAGE, KANGMEI TOWN, NANAN CITY, QUANZHOU CITY, FUJIAN CHINA
Phone Number
+86 15880910562
sales7@ca-fire.com

Hot Tags: fire protection concealed fire sprinklers, China fire protection concealed fire sprinklers manufacturers, suppliers, factory, Concealed Fire Sprinkler, Concealed Sprinkler, Fire Sprinklers
Send Inquiry
You Might Also Like











