Home - Products - Fire Sprinklers - Details
Concealed Pendant Sprinkler Head
video
Concealed Pendant Sprinkler Head

Concealed Pendant Sprinkler Head

The concealed pendant sprinkler head is an automatic fire protection device. Hidden in ceilings, it triggers via heat-sensitive parts in fires, deploying to spray water and extinguish flames, protecting buildings and occupants.

Description

Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of concealed pendant sprinkler head in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.

 

concealed pendant sprinkler head

 

Fire sprinkler 67
 
 

concealed pendant sprinkler head

The concealed pendant sprinkler head is a pivotal component of modern fire suppression systems, merging critical safety functions with architectural practicality. Its recessed, ceiling-integrated design lets it blend seamlessly into interiors-vital for hotels, offices, and luxury residences where aesthetic cohesion is prioritized, avoiding the cluttered look of exposed sprinklers while upholding protection standards.

In emergencies, its heat-sensitive element triggers automatically as temperatures rise, deploying the head to release water at a fire's early stage. This swift activation curbs flame spread, minimizes damage to structures/property, and buys life-saving evacuation time, drastically lowering casualty risks.

It also meets strict fire codes for design-focused spaces, bridging regulatory safety mandates and visual integrity. Its low-profile install reduces accidental tampering in high-traffic areas, boosting long-term reliability. For contemporary built environments, it's indispensable for balancing life-saving defense with polished, functional design.

 

concealed pendant sprinkler head

 

The concealed pendant sprinkler head is an automatic fire suppression device engineered for discreet, effective operation in indoor spaces. It is recessed into ceilings, hidden behind a decorative cover that blends with interior decor-remaining unobtrusive during normal conditions.

In its standby state, the cover shields the sprinkler's main body, while a heat-sensitive component (usually a liquid-filled glass bulb) secures a sealing mechanism over the water outlet, blocking flow. When a fire ignites, rising ambient temperatures reach the bulb's threshold: the liquid inside expands rapidly, shattering the bulb. This releases the seal, making the decorative cover drop away and extending the sprinkler's deflector.

System water pressure then drives water through the opened outlet; the deflector disperses this water into a wide, uniform spray that targets the fire directly. This process activates automatically, curbing flame spread quickly without manual intervention, all while maintaining the space's visual coherence when not in use.

 

concealed pendant sprinkler head--

Daily Maintenance Checks for Concealed Pendant Sprinkler Heads (Concealed State)

Daily Maintenance Checks for Concealed Pendant Sprinkler Heads (Concealed State)

 

Decorative Cover Integrity Check

Inspect the decorative cover for looseness, deformation, or cracks during daily rounds. Ensure it fits snugly into the ceiling recess-loose covers may fail to drop away when triggered. Wipe light dust gently (avoid forceful cleaning) to prevent buildup that could hinder its release. Confirm no external objects press against the cover, as this may damage its alignment for activation.

01

Heat-Sensitive Component Inspection

Check the external condition of the heat-sensitive element (e.g., glass bulb) for visible cracks or physical damage-even minor impacts (from cleaning or decor adjustments) can compromise its function. Ensure no substances (like paint splatters) coat the element, as this may insulate it from heat, delaying or preventing activation when temperatures rise.

 

02

Sealing Mechanism & Water Outlet Check

Verify the sealing mechanism (securing the water outlet) shows no signs of water leakage (e.g., dampness around the recess). Clear light dust from the water outlet to avoid blockages-accumulated debris can restrict water flow when the sprinkler activates. Do not disassemble the seal; focus on visual checks and surface cleaning to preserve its integrity.
 

03

Ceiling Recess & Obstruction Clearance

Ensure the ceiling recess housing the sprinkler is structurally intact (no warping or cracks) to avoid jamming the head when deployed. Clear any nearby objects (e.g., decor, furniture) that block the recess-obstructions can prevent the sprinkler from extending fully or dispersing water effectively during a fire. Maintain a clear zone around the recess at all times.

04

concealed pendant sprinkler head-Technical Parameter

 

concealed pendant sprinkler head Specification
concealed pendant sprinkler head Details
K Factor
K=5.6(K80) / K=8.0(K115)
Thread Size
R21/2"-1/2"NPT / R23/4"-3/4"NPT 
Type Pendent
Temperature sensing element Glass bulb--Q3 or Q5
Frame Finish
Chrome Plated,Brass
Deflector Finish
Chrome Plated,Stainless steel
COVER 
full brass
Fire sprinkler 68
Fire sprinkler 69
Fire sprinkler 77

  OUR CERTIFICATE:

ISO 9001
ISO 9001
ISO 14001
ISO 14001
ISO 45001
ISO 45001

 

How To Cooperate With Us?

Our address

NO.8, YUANFENG ROAD, MEIYUAN VILLAGE, KANGMEI TOWN, NANAN CITY, QUANZHOU CITY, FUJIAN CHINA

Phone Number

+86 15960762930

E-mail

alison@ca-fire.com

product-943-596

 

Learn More

 

 

 

 

 

Hot Tags: concealed pendant sprinkler head, China concealed pendant sprinkler head manufacturers, suppliers, factory

You Might Also Like