Fixed Manual Fire Monitor High-Capacity Fire Water Monitor
video
Fixed Manual Fire Monitor High-Capacity Fire Water Monitor

Fixed Manual Fire Monitor High-Capacity Fire Water Monitor

The Fixed Manual Fire Monitor is a versatile firefighting device for industrial and high-risk areas. It allows precise control of water or foam with spray and straight stream modes. The monitor supports horizontal rotation and vertical tilt, enabling long reach and flexible targeting. Durable and easy to operate, it ensures effective fire suppression and personnel safety.

Description

Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of fixed manual fire monitor high-capacity fire water monitor in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.

 

 

Products Description

 

product-800-800
 
 

CA-FIRE Fixed Manual Fire Monitor

This Fixed Manual Fire Monitor is a versatile and high-performance firefighting device designed for effective fire suppression and cooling in high-risk industrial and commercial environments. Featuring a simple and robust structure, the monitor provides reliable and stable operation while ensuring ease of use and maintenance. It is equipped with a handwheel allowing operators to switch between spray and straight stream modes, with the spray function ideal for cooling oil tanks and the straight stream function for direct firefighting. The monitor body supports horizontal rotation and vertical tilt, and it can be securely locked in position to allow safe evacuation of firefighting personnel during operation, enhancing safety on the fireground. This flexible design ensures precise targeting and efficient water or foam delivery, maximizing fire suppression efficiency. The monitor is suitable for applications in oil and chemical plants, storage tank areas, airports, warehouses, and port facilities, providing an ideal solution for both fire extinguishing and cooling operations. With its long reach, stable performance, and operator-friendly design, it offers reliable protection for property, personnel, and critical infrastructure in challenging environments.

Fixed Manual Fire Monitor Specifications

Model Flow Rate (L/s) Rated Working Pressure (MPa) Max Working Pressure (MPa) Throw Distance (m) Horizontal Rotation Angle (°) Max Elevation Angle (°) Min Depression Angle (°) Inlet Flange Operation
PS8/30W 30 0.8 1.6 ≥60 ≥180 ≥+60 ≤-15 DN100 Handle
PS8/40W 40 0.8 1.6 ≥65 ≥180 ≥+60 ≤-15 DN100 Handle
PS10/50W 50 1.0 1.6 ≥70 ≥180 ≥+60 ≤-15 DN100 Handwheel
PS10/60W 60 1.0 1.6 ≥75 ≥180 ≥+60 ≤-15 DN100 Handwheel
PS10/80W 80 1.0 1.6 ≥85 ≥180 ≥+60 ≤-15 DN100 Handwheel

Operating Instructions

Install the fire monitor base on a pipeline equipped with a shut-off valve and ensure all pre-fire preparations are complete.

In case of fire, adjust the fire monitor to the desired direction (for handle-operated monitors, hold the handle firmly), open the shut-off valve, and set the nozzle to the straight stream mode. From the operator's position, rotate the nozzle handwheel clockwise for straight stream and counterclockwise for spray mode. Aim at the fire source to extinguish the fire. The monitor supports horizontal and vertical rotation. When the nozzle is positioned at a 30° angle relative to the ground, it achieves maximum reach; adjust as needed according to the situation.

For cooling operations, set the nozzle to spray mode. From the operator's position, rotate the handwheel counterclockwise to engage spray mode (clockwise rotation switches back to straight stream).

product-800-800

product-800-800

Installation Requirements and Precautions

The fire monitor must be installed on a pipeline equipped with a shut-off valve and in accordance with relevant fire protection standards and codes.

Before installation, ensure all components are intact and free from damage. Keep the monitor in its original packaging until ready for installation to prevent contamination or mechanical damage.

Use PTFE tape (raw thread tape) for sealing threaded connections. Do not use liquid thread sealants, as excess material may interfere with the monitor's rotation or nozzle operation.

During installation, hand-tighten the monitor initially. Once resistance is felt, use an open-end wrench on the designated flats to apply the appropriate torque. Avoid fully tightening by hand, as this may create safety hazards.

Ensure the monitor is securely mounted and all moving parts rotate smoothly before use. Verify proper alignment, rotation, and elevation angles to guarantee safe and effective operation.

product-800-800

FAQ

 

Q1: What environments are this fire monitor suitable for?
A1: It is ideal for high-risk areas such as oil and chemical plants, storage tank areas, airports, warehouses, and port facilities.

Q2: How do I switch between spray and straight stream modes?
A2: From the operator's position, rotate the nozzle handwheel clockwise for straight stream and counterclockwise for spray mode.

Q3: What safety precautions should I follow during operation?
A3: Always secure the base, hold the handle or handwheel firmly, and ensure correct alignment. Keep a safe distance and follow standard firefighting procedures.

Q4: Can the monitor rotate and tilt?
A4: Yes, it supports horizontal rotation of at least 180° and vertical tilt from -15° to +60°, allowing precise aiming and maximum coverage.

Q5: What are the recommended pressures and flow rates?
A5: Depending on the model, flow rates range from 30 to 80 L/s, with rated working pressures from 0.8 to 1.0 MPa and maximum pressure up to 1.6 MPa.

 

How To Cooperate With Us?
 

Our address

NO.8, YUANFENG ROAD, MEIYUAN VILLAGE, KANGMEI TOWN, NANAN CITY, QUANZHOU CITY, FUJIAN CHINA

 
WhatsApp

+86 18160950625

 

E-mail

miki@ca-fire.com

product-943-596

 

Learn More

 

Hot Tags: fixed manual fire monitor high-capacity fire water monitor, China fixed manual fire monitor high-capacity fire water monitor manufacturers, suppliers, factory, Handwheel Control Water Monitor, Stainless Steel Lever Control Fire Water Monitor, Handwheel Control Water Foam Fire Monitor, Handwheel Control Fire Water Monitor For Fire Fighting, Fixed Firefighting Water Monitor, Stainless Steel Water Fire Monitor With Handheel

You Might Also Like

Shopping Bags