Explosion-Proof Electric Fixed-Mount Fire Monitor
video
Explosion-Proof Electric Fixed-Mount Fire Monitor

Explosion-Proof Electric Fixed-Mount Fire Monitor

This explosion-proof electric fixed-mount fire monitor features a high-strength alloy body and is compatible with a variety of water pipes. Its high-temperature and corrosion-resistant design allows for long-term operation in harsh environments such as chemical plants and docks. It is 3C-certified and supports integration with fire alarm systems. Its switchable spray modes (column/mist) ensure rapid fire extinguishing while minimizing water damage.

Description

Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of explosion-proof electric fixed-mount fire monitor in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.

 

1

Products Description

explosion-proof electric fixed-mount fire monitor

Ca-Fire Protection Co., Ltd. has developed an explosion-proof electric fixed-mount fire monitor based on the standard PSKD electric fixed-mount fire monitor. This product is suitable for use in locations with explosive levels IIA and IIB, as well as in explosive gas atmospheres with ignition characteristics in Groups T1-T6.

It supports both remote and wired control, enabling centralized control and management of the monitor via the CAN bus. Furthermore, the monitor can be used with an explosion-proof video acquisition terminal for video surveillance and management of the protected area.

It is primarily used for firefighting in flammable and explosive environments, such as petrochemicals, coal plants, and power plants, effectively enhancing fire safety in these high-risk locations.

 

Relevant explosion-proof markings are as follows:

 

Drive motor: ExdICT4 Gb

Detector: ExdICT6 Gb

Control box: Ex dⅡBT6 Gb

 

product-800-800
 
2

Main Technical Parameters

 

Model

PSKD8/30WG

PSKD8/40WG

PSKD8/50WG

PSKD10/60WG

Rated Flow

30L/S

40L/S

50L/S

60/S

Range

60m

65m

70m

75m

Rated Pressure

0.8MPa

1.0MPa

Maximum Allowable Working Pressure

1.2MPa

Maximum Spray Angle

≧90°

Horizontal Rotation Angle

0~360°

Vertical Rotation Angle

-80° ~ +65°

Power Supply

Input voltage AC220V, working voltage DC24V

Wired Control Distance

≧200m

Wireless Control Distance

≧150m

Video Function

Available (optional)

Inlet Size

DN80

Working Temperature

4℃~55℃

 

3

Products Description

product-484-658

Installation and Use Guide for Fixed Fire Water Monitors in Chemical Storage Tank Areas

 

Chemical storage tank areas are flammable, explosive, and highly corrosive. Therefore, fixed fire monitors must meet explosion-proof and corrosion-resistant standards. They should be installed 5-8 meters from the edge of the tank and utilize explosion-proof equipment (Exd II BT4). The housing is constructed of 316 stainless steel, resistant to acid and alkali corrosion.

The installation process adheres to strict explosion-proof requirements: All metal components are connected to the same potential, with a ground resistance no greater than 4Ω. The junction box is flameproof, and cables are routed through galvanized explosion-proof conduit, with joints sealed with explosion-proof sealant. Water pipes are plastic-lined steel, and flange connections are fitted with oil-resistant rubber gaskets.

Commissioning requires simulating hazardous operating conditions: Under well-ventilated conditions, flame detection sensitivity is tested using propane gas to ensure it can detect a 0.5 m2 fire source from 10 meters away. Spray stability is also tested at a water pressure of 0.6 MPa, ensuring continuous spraying for one hour without leaks. An operational linkage safety system is used: linked to the gas detection devices in the storage tank area, water monitors automatically enter alert mode when combustible gas concentrations exceed the specified limit. In the event of a fire, the foam mixing system is activated first, followed by the water monitors, creating a foam blanket to suffocate the fire. The operation panel is located in an explosion-proof control room and uses intrinsically safe buttons to prevent sparks.

Maintenance requires anti-static clothing: Inspect the explosion-proof surface with specialized tools every two weeks and apply vaseline to prevent rust. Detection devices are calibrated monthly to prevent interference from chemical gases. Corrosion-resistant seals are replaced quarterly, and the tanks are inspected for rust and perforations.

 

4

Company information

Ca-Fire Protection Co., Ltd

 

Our company is deeply involved in building a social emergency response system. It has partnered with local fire departments to establish emergency material reserves, stockpiling over 20 million yuan worth of emergency equipment, including water monitors and foam solutions. A professional emergency response team was established and participated in the handling of three hazardous chemical leaks in 2024, providing technical support and equipment. The company's developed "portable foam fire extinguishing device" has been recommended by the Ministry of Emergency Management and is widely used in grassroots fire stations.

 
01
 

product-1280-720

 
02
 

product-1280-720

 
03
 

product-1280-720

product-1280-720

product-1280-720

 

 

 

 

5

Contact with us

 

 

 

Hot Tags: explosion-proof electric fixed-mount fire monitor, China explosion-proof electric fixed-mount fire monitor manufacturers, suppliers, factory, Explosion Proof Fire Monitor, Anti Explosion Fire Monitor, Fire Monitor

You Might Also Like

Shopping Bags