Core Technology & Safety Assurance Of Fire Deluge Alarm Valve
video
Core Technology & Safety Assurance Of Fire Deluge Alarm Valve

Core Technology & Safety Assurance Of Fire Deluge Alarm Valve

The Fire Deluge Alarm Valve is an automatic water spray fire extinguishing control device designed for large-space and high-fire-risk scenarios. It is manufactured in compliance with GB 5135.5 design and manufacturing standards, adopts GB/T 1724.6 flange connection standard, with a nominal working pressure of 1.6MPa and a sealing test pressure of 3.2MPa. It enables large-area deluge-style water spraying for rapid fire extinguishing while triggering an alarm simultaneously, serving as a core fire safety equipment in industrial and civil buildings.

Description

Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of core technology & safety assurance of fire deluge alarm valve in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.

 

 

Products Description

 

product-800-800
 
 

CA-FIRE Grooved Deluge Fire Alarm Valve

This Fire Deluge Alarm Valve features precise structural design and reliable performance parameters:

Design & Connection Standards: Complies with GB 5135.5 for design and manufacturing, and GB/T 1724.6 for flange connection, ensuring installation compatibility and industry compliance.

Pressure Performance: With a nominal working pressure of 1.6MPa and a sealing test pressure of 3.2MPa, it meets pressure requirements for regular fire-extinguishing scenarios and has high-pressure sealing redundancy.

Dimension Specifications: Available in multiple models from DN50 to DN300, as well as 100(G), 150(G), and 200(G). Each model corresponds to different structural dimensions (such as h, H, A, B, M, N, D1, n-D, C, etc. – refer to the specification table), suitable for system design requirements of different pipe diameters and installation spaces.

Model Nominal Diameter (DN) Height (mm) Working Pressure Seal Test Strength Test Hydraulic Loss
ZSFM 50-350 DN50 / DN65 / DN80 / DN100 / DN125 / DN150 / DN200 / DN250 / DN300 / DN350 270 / 270 / 330 / 340 / 415 / 415 / 530 / 650 / 770 / 850 1.6 MPa 3.2 MPa 6.4 MPa <0.08 MPa
Grooved ZSFM 80-200 (G) DN80 / DN100 / DN150 / DN200 330 / 360 / 425 / 530 1.6 MPa 3.2 MPa 6.4 MPa <0.08 MPa

Key Features & Advantages

Installation Compliance: Install strictly in accordance with GB 5135.5 and local fire codes. Ensure flange connections are leak-proof; a 3.2MPa sealing pressure test must be conducted after installation.

Regular Inspection: Inspect valve disc tightness and control device sensitivity quarterly; conduct full-system pressure tests and functional tests annually to ensure reliable activation in emergencies.

Operational Safety: Non-professionals are prohibited from disassembling or adjusting valve components; clear personnel and important equipment around during activation tests to avoid water spray impact.

Identification Management: Set clear "Fire Deluge Alarm Valve" labels at valves and control devices, indicating operation procedures, emergency phone numbers, and maintenance cycles.

Ultra-Fast Response: The valve disc opens quickly, enabling large-area water spraying in a short time to effectively contain fire spread and reduce fire losses.

High Compliance: Fully complies with national standards such as GB 5135.5 and GB/T 1724.6, and has obtained authoritative fire certifications to ensure smooth project acceptance.

Multi-Model Adaptation: Covers models from DN50 to DN300 and special "(G)" models, suitable for different pipe diameters, installation spaces, and flow requirements, with strong scene compatibility.

Reliable Sealing: Designed with a 3.2MPa sealing test pressure, it has no leakage risk during long-term use, ensuring stable pressure and efficient water spraying during fire extinguishing.

product-800-800

Applications & Working Principle

The Fire Deluge Alarm Valve is suitable for scenarios where fire spreads rapidly and large-area rapid fire control is required. Typical applications include:

Industrial Fields: Petrochemical plants, oil depots, painting workshops, cable ducts, large equipment rooms, and other flammable areas where fires spread easily.

Civil & Public Buildings: Large stadiums, exhibition centers, warehousing and logistics centers, data centers, high-end commercial complexes, and other large-space venues.

Special High-Risk Sites: Power distribution rooms, generator rooms, boiler rooms, and other areas with high incidence of electrical/thermal fires.

Working Principle

The Fire Deluge Alarm Valve realizes the linked workflow of "activation - water spraying - alarm" through linkage control devices (electric, pneumatic, hydraulic, or automatic fire alarm systems):

Activation Phase: When a fire detector (or manual activation device) sends a signal, the control mechanism acts, and the deluge valve disc opens rapidly.

Water Spraying & Alarm Phase: After the valve disc opens, water is sprayed through open sprinklers for large-area fire extinguishing; meanwhile, the water flow drives alarm devices such as water motors and pressure switches to issue audible and visual alarms, achieving synchronous linkage of fire extinguishing and alarming.

Reset Phase: After the fire is extinguished, the valve disc is closed through manual or automatic control devices, and the system resets to standby status.

product-800-800

product-800-800

Safety & Environmental Responsibility

Enhanced Safety – Designed to ensure leak-free operation under working pressures up to 1.6 MPa. Grooved connections minimize joint failures and maintain system integrity during emergencies.

Reliable Fire Protection – Fast and secure grooved installation ensures the valve functions properly when activated, protecting lives and property.

Environmental Consideration – Grooved connections reduce the need for welding, flanges, and excessive fittings, lowering material waste and energy consumption during installation.

Sustainable Maintenance – Easy disassembly and reassembly allow for inspections and repairs without cutting or discarding pipe sections, reducing environmental impact.

 

FAQ

 

Installation Compliance: Install strictly in accordance with GB 5135.5 and local fire codes. Ensure flange connections are leak-proof; a 3.2MPa sealing pressure test must be conducted after installation.

Regular Inspection: Inspect valve disc tightness and control device sensitivity quarterly; conduct full-system pressure tests and functional tests annually to ensure reliable activation in emergencies.

Operational Safety: Non-professionals are prohibited from disassembling or adjusting valve components; clear personnel and important equipment around during activation tests to avoid water spray impact.

Identification Management: Set clear "Fire Deluge Alarm Valve" labels at valves and control devices, indicating operation procedures, emergency phone numbers, and maintenance cycles.

 

 

How To Cooperate With Us?
 

Our address

NO.8, YUANFENG ROAD, MEIYUAN VILLAGE, KANGMEI TOWN, NANAN CITY, QUANZHOU CITY, FUJIAN CHINA

 
WhatsApp

+86 18160950625

 

E-mail

miki@ca-fire.com

product-943-596

 

Learn More

 

Hot Tags: core technology & safety assurance of fire deluge alarm valve, China core technology & safety assurance of fire deluge alarm valve manufacturers, suppliers, factory, Deluge Valve Alarm Check Valve, Automatic Deluge Valve Sprinkler System, Deluge Valves

You Might Also Like

Shopping Bags