CA-FIRE Automatic Tracking & Positioning Jet Fire Extinguishing Device Product Introduction For ZDMS Series Automatic Tracking & Positioning Jet Fire Extinguishing Device (Models: ZDMS0.6 5S/10S; Control Box: ZDMAN-NX; Central Control Cabinet: ZDM-ZK01) 0. Company Introduction CA-FIRE...
Description
Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of ca-fire automatic tracking & positioning jet fire extinguishing device in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.
CA-FIRE Automatic Tracking & Positioning Jet Fire Extinguishing Device Product Introduction
For ZDMS Series Automatic Tracking & Positioning Jet Fire Extinguishing Device (Models: ZDMS0.6 5S/10S; Control Box: ZDMAN-NX; Central Control Cabinet: ZDM-ZK01)
0. Company Introduction
CA-FIRE Fire Protection Co., LTD, founded in 2012 and located in Quanzhou, China, specializes in the research, development, and manufacturing of high-quality firefighting equipment. Our product portfolio covers FM-certified fire sprinklers, hydrants, alarm valves, foam systems, and CCC/CE-certified nozzles. We are committed to delivering dependable, long-lasting, and compliant fire safety solutions for residential, commercial, and industrial properties across the globe.CA-FIRE's product range caters to diverse fire protection demands, including Fire Sprinklers; Indoor & Outdoor Fire Hydrants; Alarm Valves (Wet/Deluge/Explosion-Proof Types); Foam Systems (Bladder Tanks, Generators); Fire Nozzles, Water Monitors & Hoses; Hose Reels, Couplings & Accessories; and Intelligent Fire Extinguishing Devices (Automatic Tracking & Positioning Jets). Every product undergoes rigorous quality control and adheres to international fire safety standards, with customizable sizes and solutions available to fit specific project needs.
1. Product Overview & Core Advantages
1.1 Product Overview
The ZDMS Series Automatic Tracking & Positioning Jet Fire Extinguishing Device is an intelligent fire suppression system core, integrating flame detection, automatic tracking, precise positioning, and jet extinguishing functions. It works with on-site control boxes (ZDMAN-NX), central control cabinets (ZDM-ZK01), solenoid valves, fire pumps, and alarm systems to form a complete intelligent fire protection solution. Suitable for large-span, high-space environments, it automatically scans the protection area via ultraviolet flame detectors and infrared positioning sensors-once a fire is detected, it quickly locks the fire source, adjusts the jet angle, and activates the valve to spray water for targeted fire suppression. Supporting Ethernet and CAN bus communication, it enables remote monitoring and manual control via the central control system, ensuring efficient emergency response in large spaces.
1.2 Core Advantages
Intelligent Tracking & Precise Positioning: Equipped with dual-level sensors (ultraviolet flame detector + infrared positioning sensor) for fast fire source identification and high-precision positioning; supports post-installation calibration to ensure jet accuracy.
Flexible Installation Modes: Compatible with wall/column mounting, hollow suspension, ceiling extension, and terminal installation-adapting to diverse large-space layouts (warehouses, stadiums, exhibition halls).
Dual Communication & Remote Control: Supports on-site CAN bus and remote Ethernet communication; central control cabinet (ZDM-ZK01) enables centralized management, video surveillance, and remote operation, improving management efficiency.
Reliable Operational Protection: Features waterproof, dustproof, and impact-resistant design; detection components are protected against debris blocking, ensuring stable operation in harsh industrial environments.
Strong System Compatibility: Links seamlessly with fire pumps, alarm systems, and signal valves; supports multi-device networking (hand-in-hand CAN bus wiring) for large-area coverage.
Adjustable Sensitivity & Parameterization: Sensitivity of flame detectors and positioning sensors can be adjusted to avoid false activation caused by on-site interference (e.g., high-temperature equipment, strong light).
2. Technical Specifications
2.1 Core Device Parameters
| Parameter Category | Details |
|---|---|
| Model Series | ZDMS0.6 5S/10S |
| Control Box Model | ZDMAN-NX |
| Central Control Cabinet Model | ZDM-ZK01 |
| Operating Voltage | Control Box/Cabinet: 220VAC 50Hz; Device Power Supply: 220VAC (output by control box) |
| Communication Mode | On-site: CAN bus; Remote: Ethernet |
| Detection Range | 360° full coverage (no obstacles required in protection area) |
| Reset Angle After Power-On | Raised to 65° |
| Indicator Status | Normal Operation: Long off + short on (intermittent flash); Fault: Long on + short off (slow flash); Positioning Spraying: High-frequency flash; Scanning: Steady on |
| Installation Height | Adaptable to on-site needs (calibratable via parameters) |
| Pipeline Pressure Requirement | Complies with device performance design standards; requires pressure stabilizing device (small pressure fluctuation) |
2.2 Control Box & Cabinet Parameters
| Component | Model | Dimensions (mm) | Installation Requirement | Key Functions |
|---|---|---|---|---|
| On-Site Control Box | ZDMAN-NX | 250×180×80 | 1.5m above ground | Power supply to device, CAN bus communication, address registration, local debugging |
| Central Control Cabinet | ZDM-ZK01 | 650×580×1400 | Floor placement in fire control room | Dedicated fire power input, power supply to control boxes, pump control, linkage alarm output, remote monitoring |
2.3 Cable Specification Requirements
| Cable Type | Specification | Application |
|---|---|---|
| Communication Signal Line | NH-RVSP2×1.0mm² (twisted pair); NH-RVSP2×1.5mm² (CAN bus) | On-site control box ↔ Device; Control box networking |
| Power Cable | NH-RVV3×1mm² (device power); NH-RVV3×2.5mm² (control box power) | Control box ↔ Device; Central control ↔ Control box |
| Valve Connection Cable | NH-RVV2×1mm² | Control box ↔ Solenoid valve (V1, V2) |
| Feedback Signal Cable | NH-RVV2×1mm² | Water flow indicator/signal valve ↔ Control box |
| Ethernet Cable | NH-UTP-CAT5 (T-568B standard) | Central control ↔ Camera/Control box (max length ≤100m) |
2.4 Certifications
CCC, CE
3. Installation, Debugging & Maintenance Guidelines
3.1 Installation Requirements
Pre-Installation Preparation: Install the device only after pipeline installation, flushing, and pressure testing; store properly with dust, moisture, and corrosion protection before installation.
Protection Area Requirement: No obstacles blocking detection, positioning, or jetting in the protection area; ensure 360° unobstructed view for wall-mounted devices (limit mark facing the wall).
Load-Bearing & Stability: Confirm the pipe network's load-bearing capacity at the installation point; reinforce supports if necessary to avoid shaking during jetting (ensures positioning accuracy).
Installation Details:
Handle gently to avoid impact; do not hit control/detection components or wipe sensor light-receiving surfaces by hand.
Keep the upper flange end face horizontal to ensure the device body is vertically downward.
Adjust the large-space flame detector to face downward after installation.
Clean pipelines thoroughly before installing electric valves; install a filter in front of the valve to prevent blockage.
Waterproof & Dustproof: Take protective measures against water, dust, and impact after installation.
3.2 Installation Modes
Wall/Column Mounting: Limit mark faces the wall; maintain ≥350mm distance from obstacles.
Hollow Suspension: Directly suspend on the pipe network; ensure stable fixation.
Ceiling Extension: Extend from the ceiling via connecting pipes; align with the protection area center.
Terminal Installation: Install at pipeline terminals; match with corresponding pipe diameters (DN50~DN32).
3.3 Debugging Procedures
Power-On Check: Confirm correct wiring, turn on the central control cabinet and control box power; the device resets to 65° with intermittent flashing indicators (normal operation). Troubleshoot loose connections or foreign object jams if abnormal (slow flashing = fault).
Address Registration: The device automatically registers with the control box; verify displayed address, configuration parameters, and model information. Reset (double-click "Reset") for duplicate addresses and re-register.
Channel Connection: Use the central control mouse to enter "Channel Management", search for cameras, and add them to corresponding channels (set device adding mode to "Manual").
Function Test: Conduct on-site ignition tests to verify scanning, positioning, valve opening, and jetting performance.
Parameter Calibration:
Adjust sensor sensitivity based on on-site environment to avoid false activation.
Calibrate jet position if water drop point deviates: Enter debugging mode via the control box, use arrow keys to align the jet with the fire source, and exit to save parameters.
Fine-tune installation height parameters for minor deviations (e.g., set 10m actual height to 12m).
3.4 Maintenance Recommendations
Regular Inspections: Conduct monthly visual checks-clean sensors (avoid direct contact), inspect cables for damage, and verify indicator status and communication stability.
Pipeline Maintenance: Ensure pipeline pressure meets requirements; check pressure stabilizing devices regularly to avoid large pressure fluctuations.
Interference Handling: If frequent false activation occurs (due to open flame construction, high-temperature equipment), adjust sensor sensitivity or temporarily turn off power (consult after-sales first).
Wiring Maintenance: Check CAN bus hand-in-hand wiring and cable markings; avoid mixing power and communication cables to prevent equipment damage.
System Update: Coordinate with after-sales personnel for central control software and device firmware updates to optimize performance.
4. Packaging & Transportation
Our automatic tracking & positioning jet devices are packaged in export-grade wooden crates with shock-absorbing materials to protect sensitive components (sensors, control modules). This packaging ensures stability during transit, prevents damage from handling, and guarantees products arrive in pristine condition with intact functionality.
5. Application Scenarios
Industrial Facilities: Large warehouses, logistics centers, industrial workshops, and high-bay factories.
Commercial & Public Spaces: Stadiums, exhibition centers, convention halls, shopping malls, and airport terminals.
Specialized Buildings: Gymnasiums, theaters, libraries, and large-scale office complexes.
Infrastructure: Subway stations, railway stations, and large parking garages.
Other Large Spaces: High-ceilinged retail stores, entertainment venues, and assembly plants.
6. Frequently Asked Questions (FAQ)
Q: What installation modes are available for this device?A: It supports four installation modes: wall/column mounting, hollow suspension, ceiling extension, and terminal installation-adapting to diverse large-space layouts.
Q: How to handle communication failures between the device and control box?A: Check if the CAN bus uses NH-RVSP2×1.5mm² twisted pair, wiring is hand-in-hand, and H/L terminals are not reversed; verify no loose connections or cable damage.
Q: Can the jet position be adjusted if it deviates from the fire source?A: Yes. Enter debugging mode via the on-site control box, use arrow keys to align the jet with the fire source, and exit to save calibration parameters. Minor deviations can also be fixed by adjusting installation height parameters.
Q: What is the maximum number of devices that can be managed by one central control cabinet?A: It depends on the power cable specifications: 20 devices with 1.0mm² cables, 50 devices with 2.5mm² cables, and 120 devices with 6.0mm² cables.
Q: How to avoid false activation caused by on-site interference?A: Adjust the sensitivity parameters of the ultraviolet flame detector and infrared positioning sensor; if interference is severe (e.g., strong light, high-temperature equipment), consult after-sales for professional configuration.
7. Product Comparison (vs. Competitors)
| Key Comparison Points | CA-FIRE ZDMS Series Device | Competitor A | Competitor B |
|---|---|---|---|
| International Certifications | CCC + CE | CE Only | No Major Certifications |
| Positioning Accuracy | High (support on-site calibration) | Medium (no calibration function) | Low (fixed parameters) |
| Communication Modes | CAN bus + Ethernet | CAN bus Only | Wired Only (no Ethernet) |
| Installation Flexibility | 4 Modes (wall/suspension/ceiling/terminal) | 2 Modes (wall/suspension) | 1 Mode (wall-mounted) |
| Control Functions | Remote monitoring + video linkage + manual control | Remote control Only | Local Control Only |
| Sensor Sensitivity | Adjustable (anti-interference) | Fixed (prone to false activation) | Fixed (poor adaptability) |
| Multi-Device Networking | Hand-in-hand CAN bus (unlimited quantity) | Limited to 10 devices | No Networking Function |
| After-Sales Warranty | 2 Years + Technical Support | 1 Year | No Warranty |