Horizontal Foam Bladder Tank
When the pressure water flows through the proportional mixer, part of the pressure water (3%-6%) enters the foam liquid storage tank through the branch pipe and squeezes the capsules. Then, an equal amount of foam liquid is replaced and the other part of water (97%-94%) is mixed into foam liquid in the proportional mixer and provided to the foam generating device to produce air foam for extinguishing.
Description
Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of horizontal foam bladder tank in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.
Real Product Picture

Procedures for Filling a Horizontal Foam Bladder Tank
Safety Precautions
Prior to commencing the filling procedure, ensure comprehensive safety measures are implemented. Don appropriate personal protective equipment including sturdy gloves, high-quality safety goggles, and durable protective clothing. Additionally, clear the vicinity of the tank of all impediments and potential safety risks. Conduct a meticulous inspection of the tank to identify any signs of damage or leakage.
Hose Connection
Choose a hose that is optimally sized in terms of diameter and length for the filling task. Securely attach one end of the hose to the source of the foam concentrate, ensuring an airtight connection to avert any potential leakage. Subsequently, fasten the other end of the hose to the filling inlet of the horizontal foam bladder tank, utilizing appropriate fittings and clamps to guarantee a reliable seal.
Tank Ventilation
Identify the air vent on the tank and open the vent valve. This enables air to exit the tank during the filling process, preventing pressure build-up and facilitating a seamless filling operation. Without proper ventilation, the filling process may be impeded, or the tank could sustain damage.
Initiate Slow Filling
Start the foam concentrate supply pump at a gentle flow rate. This initial slow filling phase helps avoid splashing and guarantees an even distribution of the foam concentrate within the tank. Keep a vigilant eye on the filling process, particularly at the connections, to ensure there are no leaks. The liquid level can be monitored through the sight glass or level indicator.
Flow Monitoring and Adjustment
Maintain continuous oversight of the filling procedure. Keep a close watch on the flow rate of the foam concentrate and adjust it as required. An excessively high flow rate can induce turbulence within the tank, which is undesirable. Ensure that the foam concentrate flows smoothly and that no air pockets are trapped within the tank.
Completion and Sealing
When the tank attains the desired fill level, as indicated by the level indicator, halt the supply pump. Close both the filling inlet valve and the air vent valve. Carefully disconnect the supply hose, ensuring proper drainage of any remaining foam concentrate within it. Finally, clean up any spills around the tank to uphold a safe and tidy working environment.
Hot Tags: horizontal foam bladder tank, China horizontal foam bladder tank manufacturers, suppliers, factory, Firefighting Horizontal Foam Bladder Tank, Mobile Foam Unit Foam Tank Factory Supply, Horizontal Fire Mixing Foam Bladder Tank, 100L Vertical Fire Foam Bladder Tank, Foam Bladder Tank In Firefighting Equipment, Foam Bladder Tank Manufacturers