FM Approved Fire Fighting Sprinkler
FM Approved Fire Fighting Sprinkler achieves efficient fire suppression in low-risk areas through precise flow control and standard response features, while minimizing water damage. During installation, strict adherence to FM's position, spacing, and piping specifications is required. During transportation, measures must be taken to prevent shock and moisture. During storage, control of temperature and humidity is necessary, and regular inspections are conducted. Correct use of this sprinkler ensures the reliability of the fire suppression system and maximizes the protection of life and property safety.
Description
Ca-Fire Protection Co.,Ltd is one of the most credible manufacturers and suppliers of fm approved fire fighting sprinkler in China. Welcome to wholesale custom made fire equipment products at competitive price from our factory. Contact us for more cheap products.
Products Description

FM Approved Fire Fighting Sprinkler
FM Approved Fire Fighting Sprinkler achieves efficient fire suppression in low-risk areas through precise flow control and standard response features, while minimizing water damage. During installation, strict adherence to FM's position, spacing, and piping specifications is required. During transportation, measures must be taken to prevent shock and moisture. During storage, control of temperature and humidity is necessary, and regular inspections are conducted. Correct use of this sprinkler ensures the reliability of the fire suppression system and maximizes the protection of life and property safety.
Products Features
CA-FIRE Non-Storage Fire Sprinkler – Key Features




Installation:
Distance between the splash plate and the ceiling: For upright or pendant-type sprinklers, the splash plate should be kept 75 to 150mm below the ceiling; if installed between beams, the distance should not exceed 550mm, and the vertical distance from the beam bottom surface should be within 25 to 100mm.
Obstacle avoidance: There should be no obstructions (such as ventilation ducts or lamps) within 1 meter around the sprinkler head. When the width of the ventilation duct exceeds 1.2 meters, additional sprinkler heads need to be installed below the inner surface of the duct.
Wall-mounted installation: The distance between the water spray pan of the horizontal wall-mounted sprinkler and the ceiling should be 150 to 300mm, and there should be no obstructions within 2 meters in front of it.
Maintenance:
Inspect sprinkler heads regularly for corrosion, damage, or obstructions.
Test the system periodically to verify proper activation and water flow.
Clean the sprinkler nozzle and check for debris to ensure consistent performance during emergencies.
FAQ
Q1: What types of systems are compatible with CA-FIRE Non-Storage Sprinklers?
A: They are compatible with wet and dry sprinkler systems and can be installed in commercial, industrial, and residential buildings.
Q2: How does CA-FIRE ensure product quality and reliability?
A: All products are made from high-quality alloy materials, undergo strict quality control, and meet international fire protection standards.
Q3: Does CA-FIRE provide technical support for installation or maintenance?
A: Yes, CA-FIRE offers professional technical guidance, installation instructions, and after-sales support to ensure optimal system performance.
Our address
NO.8, YUANFENG ROAD, MEIYUAN VILLAGE, KANGMEI TOWN, NANAN CITY, QUANZHOU CITY, FUJIAN CHINA
+86 15880910562
sales7@ca-fire.com

Hot Tags: fm approved fire fighting sprinkler, China fm approved fire fighting sprinkler manufacturers, suppliers, factory
Send Inquiry
You Might Also Like